Independent component analysis of fMRI data in the complex domain
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
In BOLD fMRI a series of MR images is acquired and examined for task‐related amplitude changes. These functional changes are small, so it is important to maximize detection efficiency. Virtually all fMRI processing strategies utilize magnitude information and ignore the phase, resulting in an unnecessary loss of efficiency. As the optimum way to model the phase information is not clear, a flexible modeling technique is useful. To analyze complex data sets, independent component analysis (ICA), a data‐driven approach, is proposed. In ICA, the data are modeled as spatially independent components multiplied by their respective time‐courses. There are thus three possible approaches: 1) the time‐courses can be complex‐valued, 2) the images can be complex‐valued, or 3) both the time‐courses and the images can be complex‐valued. These analytic approaches are applied to data from a visual stimulation paradigm, and results from three complex analysis models are presented and compared with magnitude‐only results. Using the criterion of the number of contiguous activated voxels at a given threshold, an average of 12–23% more voxels are detected by complex‐valued ICA estimation at a threshold of |Z| > 2.5. Additionally, preliminary results from the complex models reveal a phase modulation similar to the magnitude time‐course in some voxels, and oppositely modulated in other voxels. Magn Reson Med 48:180–192, 2002. © 2002 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Information-Maximization Approach to Blind Separation and Blind Deconvolution
Bell, A. J., & Sejnowski, T. J. (1995) · Neural Computation · doi:10.1162/neco.1995.7.6.1129 · Cited by 8,986
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212 · cited 1×
“X AS [3]”
Ogawa, S., Tank, D. W., Menon, R., Ellermann, J. M., Kim, S. G., Merkle, H., & Ugurbil, K. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.13.5951 · Cited by 3,681
A method for making group inferences from functional MRI data using independent component analysis
Calhoun, V. D., Adali, T., Pearlson, G. D., & Pekar, J. J. (2001) · Human Brain Mapping · doi:10.1002/hbm.1048 · Cited by 2,994 · cited 3×
“We recently extended ICA to provide for group inferences (13), which properly account for residual error in a statistical sense.”
BackgroundMethodSelf-citationTime course EPI of human brain function during task activation
Bandettini, P. A., Wong, E. C., Hinks, R. S., Tikofsky, R. S., & Hyde, J. S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250220 · Cited by 1,935 · cited 1×
“xj a1s1 a2s2 ... aNsN, j 1, ... ,M [ 2 ] FIG. 1. Phasor diagram of fMRI data: depiction of a voxel signal intensity, x, containing fMRI signal, s, superimposed upon baseline signal intensity, b (graph not to scale).”
BackgroundEvent-related functional magnetic resonance imaging: modelling, inference and optimization
Josephs, O., & Henson, R. N. A. (1999) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.1999.0475 · Cited by 425 · cited 1×
“Similar to magnitude-only approaches, one can attempt to find a phase change that modulates with an ideal assumed paradigm, such as a box-car (8–10).”
Background
Cited by
Cluster-extent based thresholding in fMRI analyses: Pitfalls and recommendations
Woo, C.-W., Krishnan, A., & Wager, T. D. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.12.058 · Cited by 1,253
“The use of independent component analysis (ICA; Calhoun et al., 2002) and similar data compression methods are suitable in this case; the underlying generative model for ICA involves sources distributed across many voxels.”
MethodCalhoun, V. D., & Adali, T. (2012) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2012.2211076 · Cited by 543
Self-citationMethods for cleaning the BOLD fMRI signal
Caballero-Gaudes, C., & Reynolds, R. C. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.12.018 · Cited by 542
Decoding brain states from fMRI connectivity graphs
Richiardi, J., Eryilmaz, H., Schwartz, S., Vuilleumier, P., & Van De Ville, D. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.05.081 · Cited by 310
Unmixing fMRI with independent component analysis
Calhoun, V. D., & Adali, T. (2006) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2006.1607672 · Cited by 308
Self-citation
Metadata
- Authors
- Calhoun, V. D., Adalı, T., Pearlson, G. D., van Zijl, P. C. M., & Pekar, J. J.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2002-06-27
- Volume
- 48
- Issue
- 1
- Pages
- 180-192
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2120371717
- Cited by
- 146
- References
- 6
- FWCI
- 4.43
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.