The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Determining and visualizing uncertainty in estimates of fiber orientation from diffusion tensor MRI
Abstract
Diffusion tensor MRI (DT‐MRI) permits determination of the dominant orientation of structured tissue within an image voxel. This has led to the development of 2D graphical methods for representing fiber orientation and DT‐MRI “tractography,” which aims to reconstruct the 3D trajectories of white matter fasciculi. Most contemporary fiber orientation mapping schemes and tractography algorithms employ the directional information contained in the eigenvectors of the diffusion tensor to approximate white matter fiber orientation. However, while the uncertainty associated with every estimate of an eigenvector has long been recognized, no attempts to quantify this uncertainty in vivo have been reported. Here, a method is proposed for determining confidence intervals in fiber orientation from real DT‐MRI data using the bootstrap method. This is used to construct maps of the “cone of uncertainty,” allowing simultaneous viewing of fiber orientation and its uncertainty, and to examine the relationship between orientation uncertainty and tissue anisotropy. Magn Reson Med 49:7–12, 2003. © 2003 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bootstrap methods: another look at the jackknife
Efron, B. (1979) · The Annals of Statistics · doi:10.1214/aos/1176344552 · Cited by 17,602
Basser, P. J., & Pierpaoli, C. (1996) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1996.0086 · Cited by 4,306
Estimation of the Effective Self-Diffusion Tensor from the NMR Spin Echo
Basser, P. J., Mattiello, J., & Lebihan, D. (1994) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1994.1037 · Cited by 3,650
Toward a quantitative assessment of diffusion anisotropy
Pierpaoli, C., & Basser, P. J. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360612 · Cited by 2,405
Tracking neuronal fiber pathways in the living human brain
Conturo, T. E., Lori, N. F., Cull, T. S., Akbudak, E., Snyder, A. Z., Shimony, J. S., McKinstry, R. C., Burton, H., & Raichle, M. E. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.18.10422 · Cited by 1,774
Diffusion-weighted MR imaging of anisotropic water diffusion in cat central nervous system.
Moseley, M. E., Cohen, Y., Kucharczyk, J., Mintorovitch, J., Asgari, H. S., Wendland, M. F., Tsuruda, J., & Norman, D. (1990) · Radiology · doi:10.1148/radiology.176.2.2367658 · Cited by 1,133
CBMS-NSF REGIONAL CONFERENCE SERIES IN APPLIED MATHEMATICS
Gottlieb, D., Orszag, S. A., Huber, P. J., & Roberts, F. S. (2011) · Cited by 999
Pajevic, S., & Pierpaoli, C. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200006)43:6<921::aid-mrm23>3.0.co;2-i · Cited by 763
Pajevic, S., & Pierpaoli, C. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199909)42:3<526::aid-mrm15>3.0.co;2-j · Cited by 640
Regularization of Diffusion-Based Direction Maps for the Tracking of Brain White Matter Fascicles
Poupon, C., Clark, C. A., Frouin, V., Régis, J., Bloch, I., Le Bihan, D., & Mangin, J.-F. (2000) · NeuroImage · doi:10.1006/nimg.2000.0607 · Cited by 429
Statistical artifacts in diffusion tensor MRI (DT-MRI) caused by background noise
Basser, P. J., & Pajevic, S. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200007)44:1<41::aid-mrm8>3.0.co;2-o · Cited by 318
MR color mapping of myelin fiber orientation
Douek, P., Turner, R., Pekar, J., Patronas, N., & Bihan, D. L. (1991) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199111000-00003 · Cited by 274
Glyphs for visualizing uncertainty in vector fields
Wittenbrink, C. M., Pang, A. T., & Lodha, S. K. (1996) · IEEE Transactions on Visualization and Computer Graphics · doi:10.1109/2945.537309 · Cited by 253
Mapping fiber orientation spectra in cerebral white matter with Fourier-transform diffusion MRI
Wedeen, V. J., Reese, T. G., Tuch, D. S., Weigel, M., Dou, J., Weisskoff, R. M., & Chessler, D. (2000) · Cited by 188
Jones, D. K., Williams, S. C. R., Gasston, D., Horsfield, M. A., Simmons, A., & Howard, R. (2002) · Human Brain Mapping · doi:10.1002/hbm.10018 · Cited by 179
Self-citationHigh Angular Resolution Diffusion Imaging of the Human Brain
Tuch, D. S. (1999) · Cited by 156
Pajevic, S., Aldroubi, A., & Basser, P. J. (2002) · Journal of Magnetic Resonance · doi:10.1006/jmre.2001.2452 · Cited by 148
Measuring Cortico-Cortical Connectivity Matrices with Diffusion Spectrum Imaging
Tuch, D. S., Wiegell, M. R., Reese, T. G., Belliveau, J. W., & Wedeen, V. J. (2001) · Cited by 36
Estimation of anatomical connectivity from diffusion tensor data
Koch, M., Glauche, V., Finsterbusch, J., Nolte, U., Frahm, J., & Büchel, C. (2001) · NeuroImage · doi:10.1016/s1053-8119(01)91519-8 · Cited by 21
A Probabilistic Index of Connectivity (PICo) Determined Using a Monte Carlo Approach to Streamlines.
Parker, G. J. M., Buckley, D. L., & Barker, G. J. (2002) · Cited by 10
Statistically-based reorientation of diffusion tensor field
Xu, D., Mori, S., Shen, D. G., & Davatzikos, C. A. (2003) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2002.1029368 · Cited by 7
Jones (1999) · doi:10.1002/(sici)1522-2594(199907)42:1<37::aid-mrm7>3.0.co;2-o
(1999) · doi:10.1002/1531-8249(199902)45:2<265::aid-ana21>3.0.co;2-3
Cited by
NODDI: Practical in vivo neurite orientation dispersion and density imaging of the human brain
Zhang, H., Schneider, T., Wheeler-Kingshott, C. A., & Alexander, D. C. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.03.072 · Cited by 3,288
Characterization and propagation of uncertainty in diffusion-weighted MR imaging
Behrens, T. E. J., Woolrich, M. W., Jenkinson, M., Johansen‐Berg, H., Nunes, R. G., Clare, S., Matthews, P. M., Brady, J. M., & Smith, S. M. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10609 · Cited by 3,038
White matter integrity, fiber count, and other fallacies: The do's and don'ts of diffusion MRI
Jones, D. K., Knösche, T. R., & Turner, R. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.06.081 · Cited by 2,402
Self-citationDenoising of diffusion MRI using random matrix theory
Veraart, J., Novikov, D. S., Christiaens, D., Ades-aron, B., Sijbers, J., & Fieremans, E. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.08.016 · Cited by 1,905
Perisylvian language networks of the human brain
Catani, M., Jones, D. K., & ffytche, D. H. (2005) · Annals of Neurology · doi:10.1002/ana.20319 · Cited by 1,832
Metadata
- Authors
- Jones, D. K.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2002-12-31
- Volume
- 49
- Issue
- 1
- Pages
- 7-12
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2171446004
- Cited by
- 370
- References
- 23
- FWCI
- 11.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.