The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Determining and visualizing uncertainty in estimates of fiber orientation from diffusion tensor MRI
Abstract
Diffusion tensor MRI (DT‐MRI) permits determination of the dominant orientation of structured tissue within an image voxel. This has led to the development of 2D graphical methods for representing fiber orientation and DT‐MRI “tractography,” which aims to reconstruct the 3D trajectories of white matter fasciculi. Most contemporary fiber orientation mapping schemes and tractography algorithms employ the directional information contained in the eigenvectors of the diffusion tensor to approximate white matter fiber orientation. However, while the uncertainty associated with every estimate of an eigenvector has long been recognized, no attempts to quantify this uncertainty in vivo have been reported. Here, a method is proposed for determining confidence intervals in fiber orientation from real DT‐MRI data using the bootstrap method. This is used to construct maps of the “cone of uncertainty,” allowing simultaneous viewing of fiber orientation and its uncertainty, and to examine the relationship between orientation uncertainty and tissue anisotropy. Magn Reson Med 49:7–12, 2003. © 2003 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bootstrap methods: another look at the jackknife
Efron, B. (1979) · The Annals of Statistics · doi:10.1214/aos/1176344552 · Cited by 17,602
Basser, P. J., & Pierpaoli, C. (1996) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1996.0086 · Cited by 4,306
Estimation of the Effective Self-Diffusion Tensor from the NMR Spin Echo
Basser, P. J., Mattiello, J., & Lebihan, D. (1994) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1994.1037 · Cited by 3,650
Toward a quantitative assessment of diffusion anisotropy
Pierpaoli, C., & Basser, P. J. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360612 · Cited by 2,405
Tracking neuronal fiber pathways in the living human brain
Conturo, T. E., Lori, N. F., Cull, T. S., Akbudak, E., Snyder, A. Z., Shimony, J. S., McKinstry, R. C., Burton, H., & Raichle, M. E. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.18.10422 · Cited by 1,774
Diffusion-weighted MR imaging of anisotropic water diffusion in cat central nervous system.
Moseley, M. E., Cohen, Y., Kucharczyk, J., Mintorovitch, J., Asgari, H. S., Wendland, M. F., Tsuruda, J., & Norman, D. (1990) · Radiology · doi:10.1148/radiology.176.2.2367658 · Cited by 1,133
CBMS-NSF REGIONAL CONFERENCE SERIES IN APPLIED MATHEMATICS
Gottlieb, D., Orszag, S. A., Huber, P. J., & Roberts, F. S. (2011) · Cited by 999
Pajevic, S., & Pierpaoli, C. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200006)43:6<921::aid-mrm23>3.0.co;2-i · Cited by 763
Pajevic, S., & Pierpaoli, C. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199909)42:3<526::aid-mrm15>3.0.co;2-j · Cited by 640
Regularization of Diffusion-Based Direction Maps for the Tracking of Brain White Matter Fascicles
Poupon, C., Clark, C. A., Frouin, V., Régis, J., Bloch, I., Le Bihan, D., & Mangin, J.-F. (2000) · NeuroImage · doi:10.1006/nimg.2000.0607 · Cited by 429
Cited by
NODDI: Practical in vivo neurite orientation dispersion and density imaging of the human brain
Zhang, H., Schneider, T., Wheeler-Kingshott, C. A., & Alexander, D. C. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.03.072 · Cited by 3,288
Characterization and propagation of uncertainty in diffusion-weighted MR imaging
Behrens, T. E. J., Woolrich, M. W., Jenkinson, M., Johansen‐Berg, H., Nunes, R. G., Clare, S., Matthews, P. M., Brady, J. M., & Smith, S. M. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10609 · Cited by 3,038
White matter integrity, fiber count, and other fallacies: The do's and don'ts of diffusion MRI
Jones, D. K., Knösche, T. R., & Turner, R. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.06.081 · Cited by 2,402
Self-citationDenoising of diffusion MRI using random matrix theory
Veraart, J., Novikov, D. S., Christiaens, D., Ades-aron, B., Sijbers, J., & Fieremans, E. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.08.016 · Cited by 1,905
Perisylvian language networks of the human brain
Catani, M., Jones, D. K., & ffytche, D. H. (2005) · Annals of Neurology · doi:10.1002/ana.20319 · Cited by 1,832
A diffusion tensor imaging tractography atlas for virtual in vivo dissections.
CATANI, M., & THIEBAUTDESCHOTTEN, M. (2008) · Cortex · doi:10.1016/j.cortex.2008.05.004 · Cited by 1,642
Diffusion tensor imaging and beyond
Tournier, J., Mori, S., & Leemans, A. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22924 · Cited by 921
About “axial” and “radial” diffusivities
Wheeler‐Kingshott, C. A. M., & Cercignani, M. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21965 · Cited by 885
Twenty‐five pitfalls in the analysis of diffusion MRI data
Jones, D. K., & Cercignani, M. (2010) · NMR in Biomedicine · doi:10.1002/nbm.1543 · Cited by 827
Self-citationComposite hindered and restricted model of diffusion (CHARMED) MR imaging of the human brain
Assaf, Y., & Basser, P. J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.03.042 · Cited by 856
Jones, D. K. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20033 · Cited by 773
Self-citationAndersson, J. L. R., Graham, M. S., Zsoldos, E., & Sotiropoulos, S. N. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.06.058 · Cited by 763
Thiebaut de Schotten, M., ffytche, D. H., Bizzi, A., Dell'Acqua, F., Allin, M., Walshe, M., Murray, R., Williams, S. C., Murphy, D. G. M., & Catani, M. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.07.055 · Cited by 656
Diffusion MRI fiber tractography of the brain
Jeurissen, B., Descoteaux, M., Mori, S., & Leemans, A. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3785 · Cited by 574
Assaf, Y., Freidlin, R. Z., Rohde, G. K., & Basser, P. J. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20274 · Cited by 519
Studying connections in the living human brain with diffusion MRI
JONES, D. (2008) · Cortex · doi:10.1016/j.cortex.2008.05.002 · Cited by 483
Self-citationBello, L., Gambini, A., Castellano, A., Carrabba, G., Acerbi, F., Fava, E., Giussani, C., Cadioli, M., Blasi, V., Casarotti, A., et al. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.08.031 · Cited by 416
Thiebaut de Schotten, M., Tomaiuolo, F., Aiello, M., Merola, S., Silvetti, M., Lecce, F., Bartolomeo, P., & Doricchi, F. (2014) · Cerebral Cortex · doi:10.1093/cercor/bhs351 · Cited by 353
Diffusion-Tensor MR Imaging and Tractography: Exploring Brain Microstructure and Connectivity
Nucifora, P. G. P., Verma, R., Lee, S.-K., & Melhem, E. R. (2007) · Radiology · doi:10.1148/radiol.2452060445 · Cited by 344
DTI mapping of human brain connectivity: Statistical fibre tracking and virtual dissection
Hagmann, P., Thiran, J.-P., Jonasson, L., Vandergheynst, P., Clarke, S., Maeder, P., & Meuli, R. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00142-3 · Cited by 326
Challenges and limitations of quantifying brain connectivity in vivo with diffusion MRI
Jones, D. K. (2010) · Imaging in Medicine · doi:10.2217/iim.10.21 · Cited by 321
Self-citationVernooij, M. W., Smits, M., Wielopolski, P. A., Houston, G. C., Krestin, G. P., & van der Lugt, A. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.12.041 · Cited by 316
Zhang, Y., Zhang, J., Oishi, K., Faria, A. V., Jiang, H., Li, X., Akhter, K., Rosa-Neto, P., Pike, G. B., Evans, A., et al. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.05.049 · Cited by 297
Orthogonal tensor invariants and the analysis of diffusion tensor magnetic resonance images
Ennis, D. B., & Kindlmann, G. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20741 · Cited by 276
Kinoshita, M., Yamada, K., Hashimoto, N., Kato, A., Izumoto, S., Baba, T., Maruno, M., Nishimura, T., & Yoshimine, T. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.076 · Cited by 264
Limits to anatomical accuracy of diffusion tractography using modern approaches
Schilling, K. G., Nath, V., Hansen, C., Parvathaneni, P., Blaber, J., Gao, Y., Neher, P., Aydogan, D. B., Shi, Y., Ocampo-Pineda, M., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2018.10.029 · Cited by 260
Campbell, J. S. W., Siddiqi, K., Rymar, V. V., Sadikot, A. F., & Pike, G. B. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.05.014 · Cited by 177
Sotiropoulos, S. N., Hernández-Fernández, M., Vu, A. T., Andersson, J. L., Moeller, S., Yacoub, E., Lenglet, C., Ugurbil, K., Behrens, T. E. J., & Jbabdi, S. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.04.014 · Cited by 110
Lemkaddem, A., Daducci, A., Kunz, N., Lazeyras, F., Seeck, M., Thiran, J.-P., & Vulliémoz, S. (2014) · NeuroImage: Clinical · doi:10.1016/j.nicl.2014.07.013 · Cited by 70
An Introduction to Computational Diffusion MRI: the Diffusion Tensor and Beyond
Alexander, D. C. (2006) · Mathematics and Visualization · doi:10.1007/3-540-31272-2_5 · Cited by 70
Bayesian Characterization of Uncertainty in Intra-subject Non-rigid Registration
Risholm, P., Janoos, F., Norton, I., Golby, A. J., & Wells, W. M. (2013) · Medical Image Analysis · doi:10.1016/j.media.2013.03.002 · Cited by 62
Tractography in the presence of multiple sclerosis lesions
Lipp, I., Parker, G. D., Tallantyre, E. C., Goodall, A., Grama, S., Patitucci, E., Heveron, P., Tomassini, V., & Jones, D. K. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2019.116471 · Cited by 51
Self-citation
Metadata
- Authors
- Jones, D. K.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2002-12-31
- Volume
- 49
- Issue
- 1
- Pages
- 7-12
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2171446004
- Cited by
- 370
- References
- 23
- FWCI
- 11.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.