Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 230

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Mechanism of magnetization transfer during on‐resonance water saturation. A new approach to detect mobile proteins, peptides, and lipids

van Zijl, Peter C.M., Zhou, Jinyuan, Mori, Noriko, Payen, Jean‐Francois, Wilson, David, Mori, Susumu·2003·Magnetic Resonance in Medicine

Abstract

The mechanism of magnetization transfer (MT) between water and components of the proton spectrum was studied ex vivo in a perfused cell system and in vivo in the rat brain (n = 5). Water was selectively labeled and spectral buildup consequential to transfer of longitudinal magnetization was followed as a function of time. At short mixing time (Tm), nitrogen‐bound solvent‐exchangeable protons were observed, predominantly assigned to amide groups of proteins and peptides. At longer Tm, intramolecular nuclear Overhauser enhancement (NOE) was observed in the aliphatic proton region, leading to a mobile‐macromolecule‐weighted spectrum that resembles typical protein spectra described in the literature. This effect on the proton spectrum is distinct from that of classical off‐resonance MT, which has been shown to be due to the immobile solid‐like proton pool. When studying a solution of major brain metabolites under physiological concentrations and conditions (pH), no transfer effects were observed, in line with expectations based on reduced NOE effects in rapidly tumbling molecules and the fast proton exchange rates of amino, amine, SH, and OH groups. The spectral intensities of the amide protons may serve as indicators for pH and cellular levels of mobile proteins and peptides, while the aliphatic components are representative of several types of mobile macromolecules, including proteins, peptides, and lipids. Magn Reson Med 49:440–449, 2003. © 2003 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.10398

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 230

Metadata

Authors
van Zijl, P. C. M., Zhou, J., Mori, N., Payen, J., Wilson, D., & Mori, S.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2003-03
Volume
49
Issue
3
Pages
440-449
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2066475056
Cited by
230
References
1
FWCI
3.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Mechanism of magnetization transfer during on‐resonance water saturation. A new approach to detect mobile proteins, peptides, and lipids. https://app.cochat.ai/papers/10.1002/mrm.10398
The paper
van Zijl, P. C. M., Zhou, J., Mori, N., Payen, J., Wilson, D., & Mori, S. (2003). Mechanism of magnetization transfer during on‐resonance water saturation. A new approach to detect mobile proteins, peptides, and lipids. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.10398

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.