The DOI matches its Crossref record.
Is multicomponent T2 a good measure of myelin content in peripheral nerve?
Open accessAbstract
Multicomponent T2 relaxation of normal and injured rat sciatic nerve was measured. The T2 relaxation was multiexponential, indicating the multicompartmental nature of T2 decay in nerve tissue. The size of the short, observed T2 component correlated very well with quantitative assessment of myelin using computer‐assisted histopathological image analysis of myelin. Specifically, the size of the short T2 component reflected the processes of myelin loss and remyelination accompanying Wallerian degeneration and regeneration following trauma. However, it represented all myelin present in the sample and did not distinguish between intact myelin and myelin debris. Other changes in T2 spectra were also observed and could be correlated with axonal loss and inflammation. The study also questions the validity of previously offered interpretations of T2 spectra of nerve. Magn Reson Med 49:638–645, 2003. © 2003 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
T1, T2 relaxation and magnetization transfer in tissue at 3T
Stanisz, G. J., Odrobina, E. E., Pun, J., Escaravage, M., Graham, S. J., Bronskill, M. J., & Henkelman, R. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20605 · Cited by 1,266
Self-citationMapping Infant Brain Myelination with Magnetic Resonance Imaging
Deoni, S. C. L., Mercure, E., Blasi, A., Gasston, D., Thomson, A., Johnson, M., Williams, S. C. R., & Murphy, D. G. M. (2011) · The Journal of Neuroscience · doi:10.1523/jneurosci.2106-10.2011 · Cited by 497
Myelin water imaging in multiple sclerosis: quantitative correlations with histopathology
Laule, C., Leung, E., Li, D. K., Traboulsee, A. L., Paty, D. W., MacKay, A. L., & Moore, G. R. (2006) · Multiple Sclerosis Journal · doi:10.1177/1352458506070928 · Cited by 489
Gleaning multicomponent T1 and T2 information from steady‐state imaging data
Deoni, S. C. L., Rutt, B. K., Arun, T., Pierpaoli, C., & Jones, D. K. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21704 · Cited by 472
Deoni, S. C. L., Dean, D. C., O'Muircheartaigh, J., Dirks, H., & Jerskey, B. A. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.07.037 · Cited by 390
Metadata
- Authors
- Webb, S., Munro, C. A., Midha, R., & Stanisz, G. J.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2003-03-18
- Volume
- 49
- Issue
- 4
- Pages
- 638-645
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2050722132
- Cited by
- 172
- References
- 0
- FWCI
- 3.36
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Is multicomponent T2 a good measure of myelin content in peripheral nerve? https://app.cochat.ai/papers/10.1002/mrm.10411
- The paper
- Webb, S., Munro, C. A., Midha, R., & Stanisz, G. J. (2003). Is multicomponent T2 a good measure of myelin content in peripheral nerve? Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.10411
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.