The DOI matches its Crossref record.
Dynamic, contrast‐enhanced perfusion MRI in mouse gliomas: Correlation with histopathology
Open accessAbstract
The aim of this study was to develop an MRI protocol to evaluate the growth and vascularity of implanted GL261 mouse gliomas on a 7T microimaging system. Both conventional T1‐ and T2‐weighted imaging and dynamic, contrast‐enhanced T2*‐weighted imaging were performed on 34 mice at different stages of tumor development. MRI measurements of relative cerebral blood volume (rCBV) were compared to histological assessments of microvascular density (MVD). Enhancement on postcontrast T1‐weighted images was compared to histological assessments of Evan's blue extravasation. Conventional T2‐weighted and postcontrast T1‐weighted images demonstrated tumor growth characteristics consistent with previous descriptions of GL261 glioma. Furthermore, measurements of rCBV from MRI data were in good agreement with histological measurements of MVD from the same tumors. Postcontrast enhancement on T1‐weighted images was observed at all stages of GL261 glioma progression, even before evidence of angiogenesis, indicating that the mechanism of conventional contrast enhancement in MRI does not require neovascularization. These results provide quantitative support for MRI approaches currently used to assess human brain tumors, and form the basis for future studies of angiogenesis in genetically engineered mouse brain tumor models. Magn Reson Med 49:848–855, 2003. © 2003 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The blood–brain barrier and blood–tumour barrier in brain tumours and metastases
Arvanitis, C. D., Ferraro, G. B., & Jain, R. K. (2020) · Nature Reviews Cancer · doi:10.1038/s41568-019-0205-x · Cited by 1,792
An in vivo correlate of exercise-induced neurogenesis in the adult dentate gyrus
Pereira, A. C., Huddleston, D. E., Brickman, A. M., Sosunov, A. A., Hen, R., McKhann, G. M., Sloan, R., Gage, F. H., Brown, T. R., & Small, S. A. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0611721104 · Cited by 1,353
Amide proton transfer (APT) contrast for imaging of brain tumors
Zhou, J., Lal, B., Wilson, D. A., Laterra, J., & van Zijl, P. C. M. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10651 · Cited by 660
Angiogenesis in Gliomas: Biology and Molecular Pathophysiology
Fischer, I., Gagner, J., Law, M., Newcomb, E. W., & Zagzag, D. (2005) · Brain Pathology · doi:10.1111/j.1750-3639.2005.tb00115.x · Cited by 350
Self-citationGabrusiewicz, K., Ellert-Miklaszewska, A., Lipko, M., Sielska, M., Frankowska, M., & Kaminska, B. (2011) · PLoS ONE · doi:10.1371/journal.pone.0023902 · Cited by 257
Anderson, S. A., Glod, J., Arbab, A. S., Noel, M., Ashari, P., Fine, H. A., & Frank, J. A. (2005) · Blood · doi:10.1182/blood-2004-06-2222 · Cited by 254
Ellingson, B. M. (2015) · Current Neurology and Neuroscience Reports · doi:10.1007/s11910-014-0506-0 · Cited by 132
Chen, M., Shi, J., Zhang, Y., Fu, W.-M., & Qiu, Z. (2015) · Surgical Neurology International · doi:10.4103/2152-7806.154451 · Cited by 11
Metadata
- Authors
- Cha, S., Johnson, G., Wadghiri, Y. Z., Jin, O., Babb, J., Zagzag, D., & Turnbull, D. H.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2003-04-15
- Volume
- 49
- Issue
- 5
- Pages
- 848-855
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2077166252
- Cited by
- 198
- References
- 0
- FWCI
- 5.38
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.