Amide proton transfer (APT) contrast for imaging of brain tumors
Abstract
In this work we demonstrate that specific MR image contrast can be produced in the water signal that reflects endogenous cellular protein and peptide content in intracranial rat 9L gliosarcomas. Although the concentration of these mobile proteins and peptides is only in the millimolar range, a detection sensitivity of several percent on the water signal (molar concentration) was achieved. This was accomplished with detection sensitivity enhancement by selective radiofrequency (RF) labeling of the amide protons, and by utilizing the effective transfer of this label to water via hydrogen exchange. Brain tumors were also assessed by conventional T1‐weighted, T2‐weighted, and diffusion‐weighted imaging. Whereas these commonly‐used approaches yielded heterogeneous images, the new amide proton transfer (APT) technique showed a single well‐defined region of hyperintensity that was assigned to brain tumor tissue. Magn Reson Med 50:1120–1126, 2003. © 2003 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Chemical exchange saturation transfer (CEST): what is in a name and what isn't?
van Zijl, P. C. M., & Yadav, N. N. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22761 · Cited by 1,155
Self-citationZhou, J., Tryggestad, E., Wen, Z., Lal, B., Zhou, T., Grossman, R., Wang, S., Yan, K., Fu, D.-X., Ford, E., et al. (2011) · Nature Medicine · doi:10.1038/nm.2268 · Cited by 526
Self-citationChemical exchange saturation transfer imaging and spectroscopy
Zhou, J., & Zijl, P. C. M. V. (2006) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2006.01.001 · Cited by 485
Self-citationIn vivo imaging of glucose uptake and metabolism in tumors
Walker-Samuel, S., Ramasawmy, R., Torrealdea, F., Rega, M., Rajkumar, V., Johnson, S. P., Richardson, S., Gonçalves, M., Parkes, H. G., Årstad, E., et al. (2013) · Nature Medicine · doi:10.1038/nm.3252 · Cited by 479
van Zijl, P. C. M., Lam, W. W., Xu, J., Knutsson, L., & Stanisz, G. J. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.04.045 · Cited by 339
Self-citation
Metadata
- Authors
- Zhou, J., Lal, B., Wilson, D. A., Laterra, J., & van Zijl, P. C. M.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2003-11-21
- Volume
- 50
- Issue
- 6
- Pages
- 1120-1126
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2003126239
- Cited by
- 660
- References
- 0
- FWCI
- 4.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Amide proton transfer (APT) contrast for imaging of brain tumors. https://app.cochat.ai/papers/10.1002/mrm.10651
- The paper
- Zhou, J., Lal, B., Wilson, D. A., Laterra, J., & van Zijl, P. C. M. (2003). Amide proton transfer (APT) contrast for imaging of brain tumors. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.10651
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.