Quantitative magnetization transfer mapping of bound protons in multiple sclerosis
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Quantitative analysis of magnetization transfer images has the potential to allow a more thorough characterization of the protons, both bound and free, in a tissue by extracting a number of parameters relating to the NMR properties of the protons and their local environment. This work develops previously presented techniques to produce estimates of parameters such as the bound proton fraction, f, and the transverse relaxation time of the bound pool, T2B, for the whole brain in a clinically acceptable imaging time. This is achieved by limiting the number of data collected (typically to 10); to collect 28 5‐mm slices with a reconstructed resolution of 0.94 × 0.94 mm. The protocol takes 82 sec per data point. The fitting technique is assessed against previous work and for fitting failures. Maps and analysis are presented from a group of seven controls and 20 multiple sclerosis patients. The maps show that the parameters are sensitive to tissue‐specific differences and can detect pathological change within lesions. Statistically significant differences in parameters such as T2B and f are seen between normal‐appearing white matter, multiple sclerosis lesions, and control white matter. Whole‐brain histograms of these parameters are also presented, showing differences between patients and controls. Magn Reson Med 50:83–91, 2003. © 2003 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stevenson, V. L., Parker, G. J. M., Barker, G. J., Birnie, K., Tofts, P. S., Miller, D. H., & Thompson, A. J. (2000) · Journal of the Neurological Sciences · doi:10.1016/s0022-510x(00)00339-7 · Cited by 126
Self-citation
Cited by
Magnetization transfer ratio and myelin in postmortem multiple sclerosis brain
Schmierer, K., Scaravilli, F., Altmann, D. R., Barker, G. J., & Miller, D. H. (2004) · Annals of Neurology · doi:10.1002/ana.20202 · Cited by 776
Self-citationAlexander, A. L., Hurley, S. A., Samsonov, A. A., Adluru, N., Hosseinbor, A. P., Mossahebi, P., Tromp, D. P. M., Zakszewski, E., & Field, A. S. (2011) · Brain Connectivity · doi:10.1089/brain.2011.0071 · Cited by 449
MRI in multiple sclerosis: current status and future prospects
Bakshi, R., Thompson, A. J., Rocca, M. A., Pelletier, D., Dousset, V., Barkhof, F., Inglese, M., Guttmann, C. R., Horsfield, M. A., & Filippi, M. (2008) · The Lancet Neurology · doi:10.1016/s1474-4422(08)70137-6 · Cited by 348
Quantitative magnetization transfer imaging in postmortem multiple sclerosis brain
Schmierer, K., Tozer, D. J., Scaravilli, F., Altmann, D. R., Barker, G. J., Tofts, P. S., & Miller, D. H. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20984 · Cited by 273
Self-citationHua, J., Jones, C. K., Blakeley, J., Smith, S. A., van Zijl, P. C. M., & Zhou, J. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21387 · Cited by 222
“[6] using the in vivo fitted model parameters, it can be put back into Eqs.”
MethodMR imaging of high-grade brain tumors using endogenous protein and peptide-based contrast
Wen, Z., Hu, S., Huang, F., Wang, X., Guo, L., Quan, X., Wang, S., & Zhou, J. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.02.050 · Cited by 221
“In this case, the FLAIR image showed a large heterogeneous mass with a zone of low signal intensity inside the lesion.”
BackgroundYarnykh, V. L. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23224 · Cited by 162
Gochberg, D. F., & Gore, J. C. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21143 · Cited by 159
“[5] This assumption allows one to determine kmf and pm/pf by fitting for R1 , bf , bf , and Mf(0)/Mf and numerically simulating the saturation effect of the RF inversion pulse to determine Mm(0)/M (assuming a rough estimate of T2m, a pulse duration that is much shorter than 1/R1m), and a TR 1/R1 ).”
MethodQuantitative MRI and ultrastructural examination of the cuprizone mouse model of demyelination
Thiessen, J. D., Zhang, Y., Zhang, H., Wang, L., Buist, R., Del Bigio, M. R., Kong, J., Li, X., & Martin, M. (2013) · NMR in Biomedicine · doi:10.1002/nbm.2992 · Cited by 148
MR properties of excised neural tissue following experimentally induced inflammation
Stanisz, G. J., Webb, S., Munro, C. A., Pun, T., & Midha, R. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20008 · Cited by 138
Metadata
- Authors
- Tozer, D., Ramani, A., Barker, G. J., Davies, G. R., Miller, D. H., & Tofts, P. S.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2003-06-13
- Volume
- 50
- Issue
- 1
- Pages
- 83-91
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2116030156
- Cited by
- 119
- References
- 1
- FWCI
- 4.40
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.