Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 273

The DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.

Quantitative magnetization transfer imaging in postmortem multiple sclerosis brain

Open access
Schmierer, Klaus, Tozer, Daniel J., Scaravilli, Francesco, Altmann, Daniel R., Barker, Gareth J., Tofts, Paul S., Miller, David H.·2007·Journal of Magnetic Resonance Imaging

Abstract

Purpose: To investigate the relationship of myelin content, axonal density, and gliosis with the fraction of macromolecular protons (f B) and T 2 relaxation of the macromolecular pool (T 2B) acquired using quantitative magnetization transfer (qMT) MRI in postmortem brains of subjects with multiple sclerosis (MS). Materials and Methods: f B and T 2B were acquired in unfixed postmortem brain slices of 20 subjects with MS. The myelin content, axonal count, and severity of gliosis were all quantified histologically. t‐Tests and multiple regression were used for analysis. Results: MR indices obtained in unfixed postmortem MS brains were consistent with in vivo values reported in the literature. A significant correlation was detected between Tr myelin (inversely proportional to myelin content) and 1) f B (r = –0.80, P < 0.001) and 2) axonal count (r = –0.79, P < 0.001). f B differed between 1) normal‐appearing white matter (NAWM) and remyelinated WM lesions (rWMLs) (mean: f B 6.9 [SD 2] vs. 4.0 [1.8], P = 0.01), and 2) rWMLs and demyelinated WMLs (mean: 4.2 [2.2] vs. 2.5 [1.3], P = 0.016). No association was detected between T 2B and any of the histological measures. Conclusion: f B in MS WM is dependent on myelin content and may be a tool to monitor patients with this condition. J. Magn. Reson. Imaging 2007;26:41–51. © 2007 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jmri.20984

Cites

56 of 56 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 56 references

Cited by

See all 273

Metadata

Authors
Schmierer, K., Tozer, D. J., Scaravilli, F., Altmann, D. R., Barker, G. J., Tofts, P. S., & Miller, D. H.
Venue
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Published
2007-07
Volume
26
Issue
1
Pages
41-51
ISSN
  • 1053-1807 (ISSN-L)
  • 1522-2586
OpenAlex
W1992219232
Cited by
273
References
56
FWCI
5.80
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quantitative magnetization transfer imaging in postmortem multiple sclerosis brain. https://app.cochat.ai/papers/10.1002/jmri.20984
The paper
Schmierer, K., Tozer, D. J., Scaravilli, F., Altmann, D. R., Barker, G. J., Tofts, P. S., & Miller, D. H. (2007). Quantitative magnetization transfer imaging in postmortem multiple sclerosis brain. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.20984

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.