CoChat

1H‐localized broadband 13C NMR spectroscopy of the rat brain in vivo at 9.4 T

Open access
Henry, Pierre‐Gilles, Tkáč, Ivan, Gruetter, Rolf · 2003 · Magnetic Resonance in Medicine
Cited by 76

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Localized 13 C NMR spectra were obtained from the rat brain in vivo over a broad spectral range (15–100 ppm) with minimal chemical‐shift displacement error (<10%) using semi‐adiabatic distortionless enhancement by polarization transfer (DEPT) combined with 1 H localization. A new gradient dephasing scheme was employed to eliminate unwanted coherences generated by DEPT when using surface coils with highly inhomogeneous B1 fields. Excellent sensitivity was evident from the simultaneous detection of natural abundance signals for N‐acetylaspartate, myo‐inositol, and glutamate in the rat brain in vivo at 9.4 T. After infusion of 13 C‐labeled glucose, up to 18 13 C resonances were simultaneously measured in the rat brain, including glutamate C2, C3, C4, glutamine C2, C3, C4, aspartate C2, C3, glucose C1, C6, N‐acetyl‐aspartate C2, C3, C6, as well as GABA C2, lactate C3, and alanine C3. 13 C‐13 C multiplets corresponding to multiply labeled compounds were clearly observed, suggesting that extensive isotopomer analysis is possible in vivo. This unprecedented amount of information will be useful for metabolic modeling studies aimed at understanding brain energy metabolism and neurotransmission in the rodent brain. Magn Reson Med 50:684–692, 2003. © 2003 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.10601

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

Metadata

Authors
Henry, P., Tkáč, I., & Gruetter, R.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2003-09-26
Volume
50
Issue
4
Pages
684-692
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2097407397
Cited by
76
References
4
FWCI
4.40
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.