The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
k‐t BLAST and k‐t SENSE: Dynamic MRI with high frame rate exploiting spatiotemporal correlations
Open accessAbstract
Dynamic images of natural objects exhibit significant correlations in k‐space and time. Thus, it is feasible to acquire only a reduced amount of data and recover the missing portion afterwards. This leads to an improved temporal resolution, or an improved spatial resolution for a given amount of acquisition. Based on this approach, two methods were developed to significantly improve the performance of dynamic imaging, named k‐t BLAST (Broad‐use Linear Acquisition Speed‐up Technique) and k‐t SENSE (SENSitivity Encoding) for use with a single or multiple receiver coils, respectively. Signal correlations were learned from a small set of training data and the missing data were recovered using all available information in a consistent and integral manner. The general theory of k‐t BLAST and k‐t SENSE is applicable to arbitrary k‐space trajectories, time‐varying coil sensitivities, and under‐ and overdetermined reconstruction problems. Examples from ungated cardiac imaging demonstrate a 4‐fold acceleration (voxel size 2.42 × 2.52 mm 2, 38.4 fps) with either one or six receiver coils. k‐t BLAST and k‐t SENSE are applicable to many areas, especially those exhibiting quasiperiodic motion, such as imaging of the heart, the lungs, the abdomen, and the brain under periodic stimulation. Magn Reson Med 50:1031–1042, 2003. © 2003 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Self-citationGolub, G. H., & Loan, C. F. V. (1996) · Johns Hopkins University Press eBooks · Cited by 6,027
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142
Advances in sensitivity encoding with arbitrary k‐space trajectories
Pruessmann, K. P., Weiger, M., Börnert, P., & Boesiger, P. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1241 · Cited by 1,211
Self-citationTime‐resolved contrast‐enhanced 3D MR angiography
Korosec, F. R., Frayne, R., Grist, T. M., & Mistretta, C. A. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360304 · Cited by 877
“Keyhole” method for accelerating imaging of contrast agent uptake
Van Vaals, J. J., Brummer, M. E., Thomas Dixon, W., Tuithof, H. H., Engels, H., Nelson, R. C., Gerety, B. M., Chezmar, J. L., & Den Boer, J. A. (1993) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880030419 · Cited by 602
Madore, B., Glover, G. H., & Pelc, N. J. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<813::aid-mrm1>3.0.co;2-s · Cited by 433
MR fluoroscopy: Technical feasibility
Riederer, S. J., Tasciyan, T., Farzaneh, F., Lee, J. N., Wright, R. C., & Herfkens, R. J. (1988) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910080102 · Cited by 370
Quantitative evaluation of several partial fourier reconstruction algorithms used in mri
McGibney, G., Smith, M. R., Nichols, S. T., & Crawley, A. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300109 · Cited by 313
Ultrafast interleaved gradient‐echo‐planar imaging on a standard scanner
McKinnon, G. C. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300512 · Cited by 277
Cardiac real-time imaging using SENSE
Weiger, M., Pruessmann, K. P., & Boesiger, P. (2000) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(200002)43:2<177::aid-mrm3>3.0.co;2-1 · Cited by 198
Self-citationShared k‐space echo planar imaging with keyhole
Zaitsev, M., Zilles, K., & Shah, N. J. (2001) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200101)45:1<109::aid-mrm1015>3.0.co;2-x · Cited by 66
Optimal scan for time-varying tomography. I. Theoretical analysis and fundamental limitations
Willis, P. N., & Bresler, Y. (1995) · IEEE Transactions on Image Processing · doi:10.1109/83.382498 · Cited by 46
Lattice-theoretic analysis of time-sequential sampling of spatiotemporal signals. I
Willis, N. P., & Bresler, Y. (1997) · IEEE Transactions on Information Theory · doi:10.1109/18.567677 · Cited by 30
Cited by
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
Lustig, M., Donoho, D. L., Santos, J. M., & Pauly, J. M. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2007.914728 · Cited by 2,246
Deep learning in bioinformatics
Min, S., Lee, B., & Yoon, S. (2016) · Briefings in Bioinformatics · doi:10.1093/bib/bbw068 · Cited by 1,465
4D flow cardiovascular magnetic resonance consensus statement
Dyverfeldt, P., Bissell, M., Barker, A. J., Bolger, A. F., Carlhäll, C.-J., Ebbers, T., Francios, C. J., Frydrychowicz, A., Geiger, J., Giese, D., et al. (2015) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-015-0174-5 · Cited by 877
Markl, M., Frydrychowicz, A., Kozerke, S., Hope, M., & Wieben, O. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23632 · Cited by 788
Metadata
- Authors
- Tsao, J., Boesiger, P., & Pruessmann, K. P.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2003-10-24
- Volume
- 50
- Issue
- 5
- Pages
- 1031-1042
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2155268695
- Cited by
- 794
- References
- 14
- FWCI
- 17.07
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.