The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Quantitative evaluation of several partial fourier reconstruction algorithms used in mri
Abstract
Partial Fourier reconstruction algorithms exploit the redundancy in magnetic resonance data sets so that half of the data is calculated during image reconstruction rather than acquired. The conjugate synthesis, Margosian, homodyne detection, Cuppen and POCS algorithms are evaluated using spatial frequency domain analysis to show their characteristics and where limitations may occur. The phase correction used in partial Fourier reconstruction is equivalent to a convolution in the frequency domain and the importance of accurately implementing this convolution is demonstrated. New reconstruction approaches, based on passing the partial data through a phase correcting, finite impulse response (FIR), digital filter are suggested. These FIR and MoFIR algorithms have a speed near that of the Margosian and homodyne detection reconstructions, but with a lower error; close to that of the Cuppen/POCS iterative approaches. Quantitative analysis of the partial Fourier algorithms, tested with three phase estimation techniques, are provided by comparing artificial and clinical data reconstructed using full and partial Fourier techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Homodyne detection in magnetic resonance imaging
Noll, D. C., Nishimura, D. G., & Macovski, A. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.79473 · Cited by 514
Halving MR imaging time by conjugation: demonstration at 3.5 kG.
Feinberg, D. A., Hale, J. D., Watts, J. C., Kaufman, L., & Mark, A. (1986) · Radiology · doi:10.1148/radiology.161.2.3763926 · Cited by 259
A fast, iterative, partial-fourier technique capable of local phase recovery
Haacke, E. M., Lindskogj, E. D., & Lin, W. (1991) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(91)90253-p · Cited by 259
Cited by
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
Yang, G., Yu, S., Dong, H., Slabaugh, G., Dragotti, P. L., Ye, X., Liu, F., Arridge, S., Keegan, J., Guo, Y., et al. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2785879 · Cited by 1,081
Advances in diffusion MRI acquisition and processing in the Human Connectome Project
Sotiropoulos, S. N., Jbabdi, S., Xu, J., Andersson, J. L., Moeller, S., Auerbach, E. J., Glasser, M. F., Hernandez, M., Sapiro, G., Jenkinson, M., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.057 · Cited by 891
k‐t BLAST and k‐t SENSE: Dynamic MRI with high frame rate exploiting spatiotemporal correlations
Tsao, J., Boesiger, P., & Pruessmann, K. P. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10611 · Cited by 794
Reeder, S. B., Pineda, A. R., Wen, Z., Shimakawa, A., Yu, H., Brittain, J. H., Gold, G. E., Beaulieu, C. H., & Pelc, N. J. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20624 · Cited by 706
Metadata
- Authors
- McGibney, G., Smith, M. R., Nichols, S. T., & Crawley, A.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1993-07
- Volume
- 30
- Issue
- 1
- Pages
- 51-59
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2103011429
- Cited by
- 313
- References
- 3
- FWCI
- 2.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantitative evaluation of several partial fourier reconstruction algorithms used in mri. https://app.cochat.ai/papers/10.1002/mrm.1910300109
- The paper
- McGibney, G., Smith, M. R., Nichols, S. T., & Crawley, A. (1993). Quantitative evaluation of several partial fourier reconstruction algorithms used in mri. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910300109
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.