The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Amide proton transfer (APT) contrast for imaging of brain tumors
Abstract
In this work we demonstrate that specific MR image contrast can be produced in the water signal that reflects endogenous cellular protein and peptide content in intracranial rat 9L gliosarcomas. Although the concentration of these mobile proteins and peptides is only in the millimolar range, a detection sensitivity of several percent on the water signal (molar concentration) was achieved. This was accomplished with detection sensitivity enhancement by selective radiofrequency (RF) labeling of the amide protons, and by utilizing the effective transfer of this label to water via hydrogen exchange. Brain tumors were also assessed by conventional T1‐weighted, T2‐weighted, and diffusion‐weighted imaging. Whereas these commonly‐used approaches yielded heterogeneous images, the new amide proton transfer (APT) technique showed a single well‐defined region of hyperintensity that was assigned to brain tumor tissue. Magn Reson Med 50:1120–1126, 2003. © 2003 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
NMR with Proteins and Nucleic Acids
Wüthrich, K. (1986) · Europhysics News · doi:10.1051/epn/19861701011 · Cited by 7,989
NMR of Proteins and Nucleic Acids
(2006) · Nuclear Magnetic Resonance · doi:10.1039/9781847555236-00336 · Cited by 5,863
Magnetization transfer contrast (MTC) and tissue water proton relaxation in vivo
Wolff, S. D., & Balaban, R. S. (1989) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910100113 · Cited by 1,482
Ward, K. M., Aletras, A. H., & Balaban, R. S. (2000) · Journal of Magnetic Resonance · doi:10.1006/jmre.1999.1956 · Cited by 1,429
Using the amide proton signals of intracellular proteins and peptides to detect pH effects in MRI
Zhou, J., Payen, J.-F., Wilson, D. A., Traystman, R. J., & van Zijl, P. C. M. (2003) · Nature Medicine · doi:10.1038/nm907 · Cited by 1,198
Self-citationMagnetization transfer in MRI: a review
Henkelman, R. M., Stanisz, G. J., & Graham, S. J. (2001) · NMR in Biomedicine · doi:10.1002/nbm.683 · Cited by 921
Griffiths, Jr. (1991) · British Journal of Cancer · doi:10.1038/bjc.1991.326 · Cited by 594
Howe, F. A., Barton, S. J., Cudlip, S. A., Stubbs, M., Saunders, D. E., Murphy, M., Wilkins, P., Opstad, K. S., Doyle, V. L., McLean, M. A., et al. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10367 · Cited by 539
The Dynamics of Water-Protein Interactions
Bryant, R. G. (1996) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.bb.25.060196.000333 · Cited by 285
Diffusion Weighting by the Trace of the Diffusion Tensor within a Single Scan
Mori, S., & Van Zijl, P. C. M. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330107 · Cited by 278
Self-citation
Cited by
Chemical exchange saturation transfer (CEST): what is in a name and what isn't?
van Zijl, P. C. M., & Yadav, N. N. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22761 · Cited by 1,155
Self-citationKim, M., Gillen, J., Landman, B. A., Zhou, J., & van Zijl, P. C. M. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21873 · Cited by 691
Self-citationLing, W., Regatte, R. R., Navon, G., & Jerschow, A. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0707666105 · Cited by 533
Zhou, J., Tryggestad, E., Wen, Z., Lal, B., Zhou, T., Grossman, R., Wang, S., Yan, K., Fu, D.-X., Ford, E., et al. (2011) · Nature Medicine · doi:10.1038/nm.2268 · Cited by 526
Self-citationChemical exchange saturation transfer imaging and spectroscopy
Zhou, J., & Zijl, P. C. M. V. (2006) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2006.01.001 · Cited by 485
Self-citationIn vivo imaging of glucose uptake and metabolism in tumors
Walker-Samuel, S., Ramasawmy, R., Torrealdea, F., Rega, M., Rajkumar, V., Johnson, S. P., Richardson, S., Gonçalves, M., Parkes, H. G., Årstad, E., et al. (2013) · Nature Medicine · doi:10.1038/nm.3252 · Cited by 479
Alternatives to Gadolinium-Based Metal Chelates for Magnetic Resonance Imaging
Viswanathan, S., Kovacs, Z., Green, K. N., Ratnakar, S. J., & Sherry, A. D. (2010) · Chemical Reviews · doi:10.1021/cr900284a · Cited by 439
MRI detection of glycogen in vivo by using chemical exchange saturation transfer imaging (glycoCEST)
van Zijl, P. C. M., Jones, C. K., Ren, J., Malloy, C. R., & Sherry, A. D. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0700281104 · Cited by 420
Self-citationArtificial reporter gene providing MRI contrast based on proton exchange
Gilad, A. A., McMahon, M. T., Walczak, P., Winnard, P. T., Raman, V., van Laarhoven, H. W. M., Skoglund, C. M., Bulte, J. W. M., & van Zijl, P. C. M. (2007) · Nature Biotechnology · doi:10.1038/nbt1277 · Cited by 392
Self-citationAmide proton transfer imaging of adult diffuse gliomas: correlation with histopathological grades
Togao, O., Yoshiura, T., Keupp, J., Hiwatashi, A., Yamashita, K., Kikuchi, K., Suzuki, Y., Suzuki, S. O., Iwaki, T., Hata, N., et al. (2014) · Neuro-Oncology · doi:10.1093/neuonc/not158 · Cited by 392
Gillies, R. J., Raghunand, N., Garcia-Martin, M. L., & Gatenby, R. A. (2004) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2004.1360409 · Cited by 351
APT‐weighted MRI: Techniques, current neuro applications, and challenging issues
Zhou, J., Heo, H., Knutsson, L., van Zijl, P. C. M., & Jiang, S. (2019) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26645 · Cited by 345
Self-citationvan Zijl, P. C. M., Lam, W. W., Xu, J., Knutsson, L., & Stanisz, G. J. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.04.045 · Cited by 339
Self-citationAmide proton transfer imaging of human brain tumors at 3T
Jones, C. K., Schlosser, M. J., van Zijl, P. C. M., Pomper, M. G., Golay, X., & Zhou, J. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20989 · Cited by 339
Self-citationPractical data acquisition method for human brain tumor amide proton transfer (APT) imaging
Zhou, J., Blakeley, J. O., Hua, J., Kim, M., Laterra, J., Pomper, M. G., & van Zijl, P. C. M. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21712 · Cited by 338
Self-citationNatural D ‐glucose as a biodegradable MRI contrast agent for detecting cancer
Chan, K. W. Y., McMahon, M. T., Kato, Y., Liu, G., Bulte, J. W. M., Bhujwalla, Z. M., Artemov, D., & van Zijl, P. C. M. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24520 · Cited by 337
Self-citationMcMahon, M. T., Gilad, A. A., Zhou, J., Sun, P. Z., Bulte, J. W. M., & van Zijl, P. C. M. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20818 · Cited by 330
Self-citationNuts and bolts of chemical exchange saturation transfer MRI
Liu, G., Song, X., Chan, K. W. Y., & McMahon, M. T. (2013) · NMR in Biomedicine · doi:10.1002/nbm.2899 · Cited by 318
Zhou, J., Wilson, D. A., Sun, P. Z., Klaus, J. A., & van Zijl, P. C. M. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20048 · Cited by 293
Self-citationHashim, A. I., Zhang, X., Wojtkowiak, J. W., Martinez, G. V., & Gillies, R. J. (2011) · NMR in Biomedicine · doi:10.1002/nbm.1644 · Cited by 265
Imaging the accumulation and suppression of tau pathology using multiparametric MRI
Holmes, H. E., Colgan, N., Ismail, O., Ma, D., Powell, N. M., O'Callaghan, J. M., Harrison, I. F., Johnson, R. A., Murray, T. K., Ahmed, Z., et al. (2016) · Neurobiology of Aging · doi:10.1016/j.neurobiolaging.2015.12.001 · Cited by 51
Magnetic resonance imaging techniques for monitoring glioma response to chemoradiotherapy
Lawrence, L. S. P., Maralani, P. J., Das, S., Sahgal, A., Stanisz, G. J., & Lau, A. Z. (2025) · Journal of Neuro-Oncology · doi:10.1007/s11060-024-04856-3 · Cited by 4
Metadata
- Authors
- Zhou, J., Lal, B., Wilson, D. A., Laterra, J., & van Zijl, P. C. M.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2003-11-21
- Volume
- 50
- Issue
- 6
- Pages
- 1120-1126
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2003126239
- Cited by
- 660
- References
- 27
- FWCI
- 4.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.