The DOI matches its Crossref record.
Hyperechoes
Open accessAbstract
A novel spin‐echo‐based refocusing strategy called a hyperecho mechanism is introduced by which the full coherence of magnetization submitted to a sequence of arbitrary RF pulses can be reinstalled. First implementations illustrate the potential of hyperecho formation—especially for Rapid Acquisition with Relaxation Enhancement (RARE) imaging, in which the full image intensity can be retrieved using a fraction of the RF power of a fully refocused sequence. The contribution of stimulated echo pathways to the hyperecho signal leads to an increased signal intensity at a given refocusing time for tissues with T1 > T2. For identical T2 contrast, longer echo times have to be used. Further possibilities for using hyperechoes in gradient‐echo sequences and for spin selection are discussed. Magn Reson Med 46:6–12, 2001. © 2001 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
de Vries, I. J. M., Lesterhuis, W. J., Barentsz, J. O., Verdijk, P., van Krieken, J. H., Boerman, O. C., Oyen, W. J. G., Bonenkamp, J. J., Boezeman, J. B., Adema, G. J., et al. (2005) · Nature Biotechnology · doi:10.1038/nbt1154 · Cited by 821
Extended phase graphs: Dephasing, RF pulses, and echoes ‐ pure and simple
Weigel, M. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24619 · Cited by 426
Optimized three‐dimensional fast‐spin‐echo MRI
Mugler, J. P. (2014) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24542 · Cited by 376
Whole-body MRI at high field: technical limits and clinical potential
Schick, F. (2005) · European Radiology · doi:10.1007/s00330-005-2678-0 · Cited by 314
Gastric distention activates satiety circuitry in the human brain
Wang, G.-J., Tomasi, D., Backus, W., Wang, R., Telang, F., Geliebter, A., Korner, J., Bauman, A., Fowler, J. S., Thanos, P. K., et al. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.11.008 · Cited by 297
Tomasi, D., Volkow, N. D., Wang, R., Telang, F., Wang, G.-J., Chang, L., Ernst, T., & Fowler, J. S. (2009) · PLoS ONE · doi:10.1371/journal.pone.0006102 · Cited by 154
Tomasi, D., Volkow, N. D., Wang, G. J., Wang, R., Telang, F., Caparelli, E. C., Wong, C., Jayne, M., & Fowler, J. S. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.10.060 · Cited by 145
Parvaz, M. A., Moeller, S. J., d'Oleire Uquillas, F., Pflumm, A., Maloney, T., Alia-Klein, N., & Goldstein, R. Z. (2017) · Addiction Biology · doi:10.1111/adb.12403 · Cited by 70
The effect of practice on a sustained attention task in cocaine abusers.
Goldstein, R. Z., Tomasi, D., Alia-Klein, N., Zhang, L., Telang, F., & Volkow, N. D. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.12.004 · Cited by 67
Association of Body Mass and Brain Activation during Gastric Distention: Implications for Obesity
Tomasi, D., Wang, G.-J., Wang, R., Backus, W., Geliebter, A., Telang, F., Jayne, M. C., Wong, C., Fowler, J. S., & Volkow, N. D. (2009) · PLoS ONE · doi:10.1371/journal.pone.0006847 · Cited by 64
Metadata
- Authors
- Hennig, J., & Scheffler, K.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2001-07
- Volume
- 46
- Issue
- 1
- Pages
- 6-12
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W4239461267
- Cited by
- 195
- References
- 0
- FWCI
- 4.49
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.