CoChat

Single‐shot EPI with signal recovery from the susceptibility‐induced losses

Open access
Song, Allen W. · 2001 · Magnetic Resonance in Medicine
Cited by 66

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

A major problem in the gradient‐recalled echo‐planar imaging (EPI) method that also uses a long echo time (TE) is the severe signal loss in regions with large static field inhomogeneities. These regions include the ventral frontal, medial temporal, and inferior temporal lobes, which experience inhomogeneities induced by susceptibility effects commonly found near air/tissue interfaces. For functional magnetic resonance imaging (fMRI) studies that use both gradient‐recalled EPI at relatively long TE and high‐field scanners, this signal loss is severe, preventing investigation of certain human cognitive processes that involve these regions, such as memory and attention. Methods have been developed to recover this signal loss; however, most of them require multiple excitations and thus compromise temporal resolution. In this report, a new technique is described which achieves good signal recovery within a single excitation. It is anticipated that this technique will prove useful for fMRI studies in inhomogeneous areas that require high temporal resolution. Magn Reson Med 46:407–411, 2001. © 2001 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.1205

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 66

Metadata

Authors
Song, A. W.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2001-07-24
Volume
46
Issue
2
Pages
407-411
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W4241665094
Cited by
66
References
4
FWCI
5.61
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.