The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
On the theoretical basis of perfusion measurements by dynamic susceptibility contrast MRI
Open accessAbstract
A quantitative analysis was undertaken to calibrate the perfusion quantification technique based on tracking the first pass of a bolus of a blood pool contrast agent. A complete simulation of the bolus passage, of the associated changes in the T2 and T signals, and of the data processing was performed using the tracer dilution theory, an analytical theory of the MR signal from living tissues and numerical simulations. The noise was excluded in the simulation in order to analyze the ultimate accuracy of the method. It is demonstrated that the relationship between the contrast agent concentration and the associated changes in the transverse relaxation rate shows essentially different forms in studied tissue and in the reference artery. This effect results in systematic deviations of the measured blood flow, blood volume, and the residue function obtained with conventional processing from their true values. The error depends on the microvascular composition, the properties of the contrast agent, and the weights of the various compartments in the total signal. The results show that dynamic susceptibility contrast MRI can reach the goal of absolute perfusion quantification only with additional input from measurements of the microvascular architecture. Alternatively, the method can be used to provide such information if the perfusion is quantified by another modality. Magn Reson Med 46:1113–1122, 2001. © 2001 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thulborn, K. R., Waterton, J. C., Matthews, P. M., & Radda, G. K. (1982) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(82)90333-6 · Cited by 1,134
Cited by
Comparative Overview of Brain Perfusion Imaging Techniques
Wintermark, M., Sesay, M., Barbier, E., Borbély, K., Dillon, W. P., Eastwood, J. D., Glenn, T. C., Grandin, C. B., Pedraza, S., Soustiel, J.-F., et al. (2005) · Stroke · doi:10.1161/01.str.0000177884.72657.8b · Cited by 592
Real‐time diffusion‐perfusion mismatch analysis in acute stroke
Straka, M., Albers, G. W., & Bammer, R. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22338 · Cited by 401
Overview of quantitative susceptibility mapping
Deistung, A., Schweser, F., & Reichenbach, J. R. (2017) · NMR in Biomedicine · doi:10.1002/nbm.3569 · Cited by 338
Principles of cerebral perfusion imaging by bolus tracking
Østergaard, L. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20460 · Cited by 289
Perfusion Magnetic Resonance Imaging: A Comprehensive Update on Principles and Techniques
Jahng, G.-H., Li, K.-L., Ostergaard, L., & Calamante, F. (2014) · Korean Journal of Radiology · doi:10.3348/kjr.2014.15.5.554 · Cited by 256
Metadata
- Authors
- Kiselev, V. G.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2001-11-15
- Volume
- 46
- Issue
- 6
- Pages
- 1113-1122
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1967408712
- Cited by
- 182
- References
- 1
- FWCI
- 5.33
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.