The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Theoretical analysis of the effects of noise on diffusion tensor imaging
Open accessAbstract
A theoretical framework is presented for understanding the effects of noise on estimates of the eigenvalues and eigenvectors of the diffusion tensor at moderate to high signal‐to‐noise ratios. Image noise produces a random perturbation of the diffusion tensor. Power series solutions to the eigenvalue equation are used to evaluate the effects of the perturbation to second order. It is shown that in anisotropic systems the expectation value of the largest eigenvalue is overestimated and the lowest eigenvalue is underestimated. Hence, diffusion anisotropy is overestimated in general. This result is independent of eigenvalue sorting bias. Furthermore, averaging eigenvalues over a region of interest produces greater bias than averaging tensors prior to diagonalization. Finally, eigenvector noise is shown to depend on the eigenvalue contrast and imposes a theoretical limit on the accuracy of simple fiber tracking schemes. The theoretical results are shown to agree with Monte Carlo simulations. Magn Reson Med 46:1174–1188, 2001. © 2001 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
Estimation of the Effective Self-Diffusion Tensor from the NMR Spin Echo
Basser, P. J., Mattiello, J., & Lebihan, D. (1994) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1994.1037 · Cited by 3,650
Diffusion tensor MR imaging of the human brain
Pierpaoli, C., Jezzard, P., Basser, P. J., Barnett, A., & Di Chiro, G. (1996) · Radiology · doi:10.1148/radiology.201.3.8939209 · Cited by 2,664
Toward a quantitative assessment of diffusion anisotropy
Pierpaoli, C., & Basser, P. J. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360612 · Cited by 2,405
Tracking neuronal fiber pathways in the living human brain
Conturo, T. E., Lori, N. F., Cull, T. S., Akbudak, E., Snyder, A. Z., Shimony, J. S., McKinstry, R. C., Burton, H., & Raichle, M. E. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.18.10422 · Cited by 1,774
Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imaging
Jones, D. K., Horsfield, M. A., & Simmons, A. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199909)42:3<515::aid-mrm14>3.0.co;2-q · Cited by 1,403
Diffusion tensor imaging of lesions and normal-appearing white matter in multiple sclerosis
Werring, D. J., Clark, C. A., Barker, G. J., Thompson, A. J., & Miller, D. H. (1999) · Neurology · doi:10.1212/wnl.52.8.1626 · Cited by 621
Determinants of anisotropic water diffusion in nerves
Beaulieu, C., & Allen, P. S. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310408 · Cited by 613
Pfefferbaum, A., Sullivan, E. V., Hedehus, M., Lim, K. O., Adalsteinsson, E., & Moseley, M. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200008)44:2<259::aid-mrm13>3.0.co;2-6 · Cited by 595
Regularization of Diffusion-Based Direction Maps for the Tracking of Brain White Matter Fascicles
Poupon, C., Clark, C. A., Frouin, V., Régis, J., Bloch, I., Le Bihan, D., & Mangin, J.-F. (2000) · NeuroImage · doi:10.1006/nimg.2000.0607 · Cited by 429
Diffusion tensor imaging can detect and quantify corticospinal tract degeneration after stroke
Werring, D. J. (2000) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.69.2.269 · Cited by 399
In vivo three-dimensional reconstruction of rat brain axonal projections by diffusion tensor imaging
Xue, R., van Zijl, P. C. M., Crain, B. J., Solaiyappan, M., & Mori, S. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199912)42:6<1123::aid-mrm17>3.0.co;2-h · Cited by 386
MRI white matter diffusion anisotropy and PET metabolic rate in schizophrenia
Buchsbaum, M. S., Tang, C. Y., Peled, S., Gudbjartsson, H., Lu, D., Hazlett, E. A., Downhill, J., Haznedar, M., Fallon, J. H., & Atlas, S. W. (1998) · NeuroReport · doi:10.1097/00001756-199802160-00013 · Cited by 371
Statistical artifacts in diffusion tensor MRI (DT-MRI) caused by background noise
Basser, P. J., & Pajevic, S. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200007)44:1<41::aid-mrm8>3.0.co;2-o · Cited by 318
Beaulieu, C., & Allen, P. S. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320506 · Cited by 240
Analytical Expressions for the b Matrix in NMR Diffusion Imaging and Spectroscopy
Mattiello, J., Basser, P. J., & Lebihan, D. (1994) · Journal of Magnetic Resonance, Series A · doi:10.1006/jmra.1994.1103 · Cited by 222
The estimation of second-order tensors, with related tests and designs
HEXT, G. R. (1963) · Biometrika · doi:10.1093/biomet/50.3-4.353 · Cited by 205
A Comparative Study of Acquisition Schemes for Diffusion Tensor Imaging Using MRI
Papadakis, N. G., Xing, D., Huang, C. L.-H., Hall, L. D., & Carpenter, T. A. (1999) · Journal of Magnetic Resonance · doi:10.1006/jmre.1998.1673 · Cited by 203
Bastin, M. E., Armitage, P. A., & Marshall, I. (1998) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(98)00098-8 · Cited by 188
Neeman, M., Freyer, J. P., & Sillerud, L. O. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910210117 · Cited by 179
Minimal gradient encoding for robust estimation of diffusion anisotropy☆
Papadakis, N. G., Murrills, C. D., Hall, L. D., Huang, C. L.-H., & Carpenter, T. A. (2000) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(00)00151-x · Cited by 149
Neeman, M., Freyer, J. P., & Sillerud, L. O. (1990) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(90)90136-w · Cited by 115
Limitations and requirements of diffusion tensor fiber tracking: an assessment using simulations
Tournier, J. ‐., Calamante, F., King, M. D., Gadian, D. G., & Connelly, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10116 · Cited by 114 · cited 1×
“[18] and [24]), and hence the eigenvalue bias by the factor 1/N (see Appendix D).”
BackgroundThe reduction of the sorting bias in the eigenvalues of the diffusion tensor
Martin, K. M., Papadakis, N. G., Huang, C. L.-H., Hall, L. D., & Carpenter, T. A. (1999) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(99)00021-1 · Cited by 34
Basser (2000) · doi:10.1002/1522-2594(200010)44:4<625::aid-mrm17>3.0.co;2-o
Cited by
Non-invasive mapping of connections between human thalamus and cortex using diffusion imaging
Behrens, T. E. J., Johansen-Berg, H., Woolrich, M. W., Smith, S. M., Wheeler-Kingshott, C. A. M., Boulby, P. A., Barker, G. J., Sillery, E. L., Sheehan, K., Ciccarelli, O., et al. (2003) · Nature Neuroscience · doi:10.1038/nn1075 · Cited by 2,330
The B‐matrix must be rotated when correcting for subject motion in DTI data
Leemans, A., & Jones, D. K. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21890 · Cited by 1,281
White matter tractography using diffusion tensor deflection
Lazar, M., Weinstein, D. M., Tsuruda, J. S., Hasan, K. M., Arfanakis, K., Meyerand, M. E., Badie, B., Rowley, H. A., Haughton, V., Field, A., et al. (2003) · Human Brain Mapping · doi:10.1002/hbm.10102 · Cited by 582
Diffusion Tensor MR Imaging and Fiber Tractography: Theoretic Underpinnings
Mukherjee, P., Berman, J. I., Chung, S. W., Hess, C. P., & Henry, R. G. (2008) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1051 · Cited by 521
Alexander, A. L., Hurley, S. A., Samsonov, A. A., Adluru, N., Hosseinbor, A. P., Mossahebi, P., Tromp, D. P. M., Zakszewski, E., & Field, A. S. (2011) · Brain Connectivity · doi:10.1089/brain.2011.0071 · Cited by 449
Metadata
- Authors
- Anderson, A. W.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2001-11-15
- Volume
- 46
- Issue
- 6
- Pages
- 1174-1188
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2051781844
- Cited by
- 280
- References
- 25
- FWCI
- 7.01
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.