The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Accurate quantification of in vivo31P NMR signals using the variable projection method and prior knowledge
Abstract
Free induction decay signals are analyzed by fitting a model function directly in the time domain. No starting values are needed for linear model parameters, and omission of corrupted data points poses no problems. A significant gain of accuracy is achieved by imposing prior knowledge about the model parameters. © 1988 Academic Press, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Differentiation of Pseudo-Inverses and Nonlinear Least Squares Problems Whose Variables Separate
Golub, G. H., & Pereyra, V. (1973) · SIAM Journal on Numerical Analysis · doi:10.1137/0710036 · Cited by 1,430
Estimating the parameters of exponentially damped sinusoids and pole-zero modeling in noise
Kumaresan, R., & Tufts, D. (1982) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1982.1163974 · Cited by 867
Image-selected in Vivo spectroscopy (ISIS). A new technique for spatially selective nmr spectroscopy
Ordidge, R. J., Connelly, A., & Lohman, J. A. B. (1986) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(86)90031-4 · Cited by 811
GOLUBf, G. H., & Pereyra, V. L. (1973) · Cited by 732
Barkhuijsen, H., de Beer, R., Bovée, W. M. M. J., et al. (1985) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(85)90187-8 · Cited by 480
Kung, S. Y., Arun, K. S., & Bhaskar Rao, D. V. (1983) · Journal of the Optical Society of America · doi:10.1364/josa.73.001799 · Cited by 406
Cited by
Improved Method for Accurate and Efficient Quantification of MRS Data with Use of Prior Knowledge
Vanhamme, L., van den Boogaart, A., & Van Huffel, S. (1997) · Journal of Magnetic Resonance · doi:10.1006/jmre.1997.1244 · Cited by 1,627
Java-based graphical user interface for the MRUI quantitation package
Naressi, A., Couturier, C., Devos, J. M., Janssen, M., Mangeat, C., Beer, R. D., & Graveron-Demilly, D. (2001) · Magnetic Resonance Materials in Physics, Biology and Medicine · doi:10.1007/bf02668096 · Cited by 1,003
Separable nonlinear least squares: the variable projection method and its applications
Golub, G., & Pereyra, V. (2003) · Inverse Problems · doi:10.1088/0266-5611/19/2/201 · Cited by 760
Quantitation of magnetic resonance spectroscopy signals: the jMRUI software package
Stefan, D., Cesare, F. D., Andrasescu, A., Popa, E., Lazariev, A., Vescovo, E., Strbak, O., Williams, S., Starcuk, Z., Cabanas, M., et al. (2009) · Measurement Science and Technology · doi:10.1088/0957-0233/20/10/104035 · Cited by 514
Self-citationMetabonomics: Metabolic processes studied by NMR spectroscopy of biofluids
Lindon, J. C., Nicholson, J. K., Holmes, E., & Everett, J. R. (2000) · Concepts in Magnetic Resonance · doi:10.1002/1099-0534(2000)12:5<289::aid-cmr3>3.0.co;2-w · Cited by 460
Naressi, A., Couturier, C., Castang, I., de Beer, R., & Graveron-Demilly, D. (2001) · Computers in Biology and Medicine · doi:10.1016/s0010-4825(01)00006-3 · Cited by 459
Self-citationLindon, J. C., Nicholson, J. K., & Everett, J. R. (1999) · Annual Reports on NMR Spectroscopy · doi:10.1016/s0066-4103(08)60035-6 · Cited by 395
Diamant, M., Lamb, H. J., Groeneveld, Y., Endert, E. L., Smit, J. W. A., Bax, J. J., Romijn, J. A., de Roos, A., & Radder, J. K. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00625-9 · Cited by 372
Rossiter, H. B., Ward, S. A., Kowalchuk, J. M., Howe, F. A., Griffiths, J. R., & Whipp, B. J. (2002) · The Journal of Physiology · doi:10.1113/jphysiol.2001.012910 · Cited by 364
Near, J., Harris, A. D., Juchem, C., Kreis, R., Marjańska, M., Öz, G., Slotboom, J., Wilson, M., & Gasparovic, C. (2021) · NMR in Biomedicine · doi:10.1002/nbm.4257 · Cited by 342
Wilson, M., Reynolds, G., Kauppinen, R. A., Arvanitis, T. N., & Peet, A. C. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22579 · Cited by 332
Cramér–Rao bounds: an evaluation tool for quantitation
Cavassila, S., Deval, S., Huegen, C., van Ormondt, D., & Graveron‐Demilly, D. (2001) · NMR in Biomedicine · doi:10.1002/nbm.701 · Cited by 331
Self-citationTime‐domain semi‐parametric estimation based on a metabolite basis set
Ratiney, H., Sdika, M., Coenradie, Y., Cavassila, S., Ormondt, D. V., & Graveron‐Demilly, D. (2005) · NMR in Biomedicine · doi:10.1002/nbm.895 · Cited by 295
Rossiter, H. B., Ward, S. A., Doyle, V. L., Howe, F. A., Griffiths, J. R., & Whipp, B. J. (1999) · The Journal of Physiology · doi:10.1111/j.1469-7793.1999.0921p.x · Cited by 292
Tiikkainen, M., Bergholm, R., Vehkavaara, S., Rissanen, A., Häkkinen, A.-M., Tamminen, M., Teramo, K., & Yki-Järvinen, H. (2003) · Diabetes · doi:10.2337/diabetes.52.3.701 · Cited by 271
SALA, E., ROCA, J., MARRADES, R. M., ALONSO, J., GONZALEZ de SUSO, J. M., MORENO, A., BARBERÁ, J. A., NADAL, J., de JOVER, L., RODRIGUEZ-ROISIN, R., et al. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.159.6.9804136 · Cited by 272
Jung, W.-I., Sieverding, L., Breuer, J., Hoess, T., Widmaier, S., Schmidt, O., Bunse, M., van Erckelens, F., Apitz, J., Lutz, O., et al. (1998) · Circulation · doi:10.1161/01.cir.97.25.2536 · Cited by 197
(2002) · PubMed · Cited by 101
Rico‐Sanz, J., Hajnal, J. V., Thomas, E. L., Mierisová, Ŝ., Ala‐Korpela, M., & Bell, J. D. (1998) · The Journal of Physiology · doi:10.1111/j.1469-7793.1998.615bk.x · Cited by 88
Turner, C. E., Russell, B. R., & Gant, N. (2015) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2015.06.018 · Cited by 19
Weighted averaging in spectroscopic studies improves statistical power
Miller, J. J., Cochlin, L., Clarke, K., & Tyler, D. J. (2017) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26615 · Cited by 16
Metadata
- Authors
- van der Veen, J. W. C., de Beer, R., Luyten, P. R., & van Ormondt, D.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1988-01
- Volume
- 6
- Issue
- 1
- Pages
- 92-98
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2016996526
- Cited by
- 363
- References
- 6
- FWCI
- 7.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.