The DOI matches its Crossref record.
Direct FLASH MR imaging of magnetic field inhomogeneities by gradient compensation
Abstract
MR images based on gradient echoes are sensitive to artifacts caused by inhomogeneities of the static magnetic field. This paper describes the effects of local gradients in rapid FLASH MR images and presents a way of directly imaging affected areas. The idea is to compensate for signal losses due to mutual cancellation of dephased magnetizations by deliberate “misadjustments” of the refocusing part of the slice selection gradient. In contrast to conventional field imaging techniques no three‐dimensional data acquisition or subsequent Fourier analysis is required to obtain images at a particular gradient strength. Conventional as well as inhomogeneity compensated FLASH images have been obtained on phantoms and human heads using a 2.35‐T 40‐cm magnet and a 1.5‐T whole‐body system, respectively. © 1988 Academic Press, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Oxygenation‐sensitive contrast in magnetic resonance image of rodent brain at high magnetic fields
Ogawa, S., Lee, T., Nayak, A. S., & Glynn, P. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140108 · Cited by 2,266
Neural responses during anticipation of a primary taste reward
O'Doherty, J. P., Deichmann, R., Critchley, H. D., & Dolan, R. J. (2002) · Neuron · doi:10.1016/s0896-6273(02)00603-7 · Cited by 1,076
Imaging iron stores in the brain using magnetic resonance imaging
Haacke, E. M., Cheng, N. Y. C., House, M. J., Liu, Q., Neelavalli, J., Ogg, R. J., Khan, A., Ayaz, M., Kirsch, W., & Obenaus, A. (2005) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2004.10.001 · Cited by 995
Optimized EPI for fMRI studies of the orbitofrontal cortex
Deichmann, R., Gottfried, J. A., Hutton, C., & Turner, R. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00073-9 · Cited by 821
Frahm, J., Bruhn, H., Gyngell, M. L., Merboldt, K. D., Hänicke, W., & Sauter, R. (1989) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910090110 · Cited by 709
Self-citationOjemann, J. G., Akbudak, E., Snyder, A. Z., McKinstry, R. C., Raichle, M. E., & Conturo, T. E. (1997) · NeuroImage · doi:10.1006/nimg.1997.0289 · Cited by 694
Weiskopf, N., Hutton, C., Josephs, O., & Deichmann, R. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.07.029 · Cited by 475
Marques, J. P., & Bowtell, R. (2005) · Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering · doi:10.1002/cmr.b.20034 · Cited by 434
Gelman, N., Gorell, J. M., Barker, P. B., Savage, R. M., Spickler, E. M., Windham, J. P., & Knight, R. A. (1999) · Radiology · doi:10.1148/radiology.210.3.r99fe41759 · Cited by 373
fMRI of emotional responses to odors:
Royet, J.-P., Plailly, J., Delon-Martin, C., Kareken, D. A., & Segebarth, C. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00388-4 · Cited by 348
Brain or veinoxygenation or flow? On signal physiology in functional MRI of human brain activation
Frahm, J., Merboldt, K., Hänicke, W., Kleinschmidt, A., & Boecker, H. (1994) · NMR in Biomedicine · doi:10.1002/nbm.1940070108 · Cited by 342
Self-citationFunctional neuroimaging of the olfactory system in humans
Zald, D. H., & Pardo, J. V. (2000) · International Journal of Psychophysiology · doi:10.1016/s0167-8760(99)00110-5 · Cited by 334
Assessment of relative brain iron concentrations using T2‐weighted and T2*‐weighted MRI at 3 Tesla
Ordidge, R. J., Gorell, J. M., Deniau, J. C., Knight, R. A., & Helpern, J. A. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320309 · Cited by 323
Theory and application of static field inhomogeneity effects in gradient‐echo imaging
Reichenbach, J. R., Venkatesan, R., Yablonskiy, D. A., Thompson, M. R., Lai, S., & Haacke, E. M. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070203 · Cited by 285
Compensation of susceptibility-induced bold sensitivity losses in echo-planar fMRI imaging
Deichmann, R., Josephs, O., Hutton, C., Corfield, D. R., & Turner, R. (2002) · NeuroImage · doi:10.1006/nimg.2001.0985 · Cited by 253
Lateralization of olfactory processes
Royet, J.-P. (2004) · Chemical Senses · doi:10.1093/chemse/bjh067 · Cited by 220
Juchem, C., Umesh Rudrapatna, S., Nixon, T. W., & de Graaf, R. A. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2014.11.011 · Cited by 74
Metadata
- Authors
- Frahm, J., Merboldt, K., & Hänicke, W.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1988-04
- Volume
- 6
- Issue
- 4
- Pages
- 474-480
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2077187614
- Cited by
- 228
- References
- 0
- FWCI
- 2.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.