The DOI matches its Crossref record.
A comparison of one‐shot and recovery methods in T1 imaging
Abstract
Spin–lattice (T1) relaxation times are conventionally estimated using inversion recovery or saturation recovery sequences. Such “recovery” methods are limited in magnetic resonance imaging by the long times required to collect multiple points along the T1 relaxation curve. This problem can be overcome by the use of “one‐shot” methods, which collect all points along the relaxation curve in a single excitation. We have compared the relative efficiency of these methods, on the basis of the signal‐to‐noise ratio obtained in the calculated T1 image from an exam time of fixed duration. We have found that a one‐shot method using stimulated echoes has a poor efficiency. However, a method based on a technique first proposed by Look and Locker has an efficiency that is almost equal to the inversion recovery method and therefore possesses highly favorable properties for T1 imaging. © 1988 Academic Press, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Magnetic resonance fingerprinting
Ma, D., Gulani, V., Seiberlich, N., Liu, K., Sunshine, J. L., Duerk, J. L., & Griswold, M. A. (2013) · Nature · doi:10.1038/nature11971 · Cited by 1,577
Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady state
Deoni, S. C. L., Rutt, B. K., & Peters, T. M. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10407 · Cited by 744
Compressed sensing reconstruction for magnetic resonance parameter mapping
Doneva, M., Börnert, P., Eggers, H., Stehning, C., Sénégas, J., & Mertins, A. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22483 · Cited by 326
On the accuracy of T1 mapping: Searching for common ground
Stikov, N., Boudreau, M., Levesque, I. R., Tardif, C. L., Barral, J. K., & Pike, G. B. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25135 · Cited by 285
Flowers, H. L., Silver, F. L., Fang, J., Rochon, E., & Martino, R. (2013) · Journal of Communication Disorders · doi:10.1016/j.jcomdis.2013.04.001 · Cited by 249
Metadata
- Authors
- Crawley, A. P., & Henkelman, R. M.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1988-05
- Volume
- 7
- Issue
- 1
- Pages
- 23-34
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2123005841
- Cited by
- 197
- References
- 0
- FWCI
- 3.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A comparison of one‐shot and recovery methods in T1 imaging. https://app.cochat.ai/papers/10.1002/mrm.1910070104
- The paper
- Crawley, A. P., & Henkelman, R. M. (1988). A comparison of one‐shot and recovery methods in T1 imaging. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910070104
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.