The DOI matches its Crossref record.
A comparison of one‐shot and recovery methods in T1 imaging
Abstract
Spin–lattice (T1) relaxation times are conventionally estimated using inversion recovery or saturation recovery sequences. Such “recovery” methods are limited in magnetic resonance imaging by the long times required to collect multiple points along the T1 relaxation curve. This problem can be overcome by the use of “one‐shot” methods, which collect all points along the relaxation curve in a single excitation. We have compared the relative efficiency of these methods, on the basis of the signal‐to‐noise ratio obtained in the calculated T1 image from an exam time of fixed duration. We have found that a one‐shot method using stimulated echoes has a poor efficiency. However, a method based on a technique first proposed by Look and Locker has an efficiency that is almost equal to the inversion recovery method and therefore possesses highly favorable properties for T1 imaging. © 1988 Academic Press, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Magnetic resonance fingerprinting
Ma, D., Gulani, V., Seiberlich, N., Liu, K., Sunshine, J. L., Duerk, J. L., & Griswold, M. A. (2013) · Nature · doi:10.1038/nature11971 · Cited by 1,577
Modified Look‐Locker inversion recovery (MOLLI) for high‐resolution T1 mapping of the heart
Messroghli, D. R., Radjenovic, A., Kozerke, S., Higgins, D. M., Sivananthan, M. U., & Ridgway, J. P. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20110 · Cited by 1,349
Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady state
Deoni, S. C. L., Rutt, B. K., & Peters, T. M. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10407 · Cited by 744
Cheng, H. M., & Wright, G. A. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20791 · Cited by 351
Compressed sensing reconstruction for magnetic resonance parameter mapping
Doneva, M., Börnert, P., Eggers, H., Stehning, C., Sénégas, J., & Mertins, A. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22483 · Cited by 326
On the accuracy of T1 mapping: Searching for common ground
Stikov, N., Boudreau, M., Levesque, I. R., Tardif, C. L., Barral, J. K., & Pike, G. B. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25135 · Cited by 285
“1 cos ucosaErE1ðcosaE2Þ 1 [8]”
Wright, P. J., Mougin, O. E., Totman, J. J., Peters, A. M., Brookes, M. J., Coxon, R., Morris, P. E., Clemence, M., Francis, S. T., Bowtell, R. W., et al. (2008) · Magnetic Resonance Materials in Physics, Biology and Medicine · doi:10.1007/s10334-008-0104-8 · Cited by 263
Flowers, H. L., Silver, F. L., Fang, J., Rochon, E., & Martino, R. (2013) · Journal of Communication Disorders · doi:10.1016/j.jcomdis.2013.04.001 · Cited by 249
Neuwelt, E. A., Várallyay, C. G., Manninger, S., Solymosi, D., Haluska, M., Hunt, M. A., Nesbit, G., Stevens, A., Jerosch-Herold, M., Jacobs, P. M., et al. (2007) · Neurosurgery · doi:10.1227/01.neu.0000255350.71700.37 · Cited by 184
Accounting for biological aggregation in heating and imaging of magnetic nanoparticles
Etheridge, M. L., Hurley, K. R., Zhang, J., Jeon, S., Ring, H. L., Hogan, C., Haynes, C. L., Garwood, M., & Bischof, J. C. (2014) · TECHNOLOGY · doi:10.1142/s2339547814500198 · Cited by 115
European Society of Radiology (ESR) (2015) · Insights into Imaging · doi:10.1007/s13244-015-0403-3 · Cited by 59
Van Steenkiste, G., Poot, D. H. J., Jeurissen, B., den Dekker, A. J., Vanhevel, F., Parizel, P. M., & Sijbers, J. (2017) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26262 · Cited by 20
Goldenberg, J. M., Cárdenas‐Rodríguez, J., & Pagel, M. D. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27439 · Cited by 10
Grieve (2000) · doi:10.1002/(sici)1522-2594(200005)43:5
Metadata
- Authors
- Crawley, A. P., & Henkelman, R. M.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1988-05
- Volume
- 7
- Issue
- 1
- Pages
- 23-34
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2123005841
- Cited by
- 197
- References
- 0
- FWCI
- 3.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.