The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady state
Abstract
A novel, fully 3D, high‐resolution T1 and T2 relaxation time mapping method is presented. The method is based on steady‐state imaging with T1 and T2 information derived from either spoiling or fully refocusing the transverse magnetization following each excitation pulse. T1 is extracted from a pair of spoiled gradient recalled echo (SPGR) images acquired at optimized flip angles. This T1 information is combined with two refocused steady‐state free precession (SSFP) images to determine T2. T1 and T2 accuracy was evaluated against inversion recovery (IR) and spin‐echo (SE) results, respectively. Error within the T1 and T2 maps, determined from both phantom and in vivo measurements, is approximately 7% for T1 between 300 and 2000 ms and 7% for T2 between 30 and 150 ms. The efficiency of the method, defined as the signal‐to‐noise ratio (SNR) of the final map per voxel volume per square root scan time, was evaluated against alternative mapping methods. With an efficiency of three times that of multipoint IR and three times that of multiecho SE, our combined approach represents the most efficient of those examined. Acquisition time for a whole brain T1 map (25 × 25 × 10 cm) is less than 8 min with 1 mm 3 isotropic voxels. An additional 7 min is required for an identically sized T2 map and postprocessing time is less than 1 min on a 1 GHz PIII PC. The method therefore permits real‐time clinical acquisition and display of whole brain T1 and T2 maps for the first time. Magn Reson Med 49:515–526, 2003. © 2003 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Detre, J. A., Leigh, J. S., Williams, D. S., & Koretsky, A. P. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910230106 · Cited by 1,571
Pauly, J., Le Roux, P., Nishimura, D., & Macovski, A. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.75611 · Cited by 800
Vymazal, J., Righini, A., Brooks, R. A., Canesi, M., Mariani, C., Leonardi, M., & Pezzoli, G. (1999) · Radiology · doi:10.1148/radiology.211.2.r99ma53489 · Cited by 342
Optimizing the precision in T1 relaxation estimation using limited flip angles
Wang, H. Z., Riederer, S. J., & Lee, J. N. (1987) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910050502 · Cited by 271
A comparison of one‐shot and recovery methods in T1 imaging
Crawley, A. P., & Henkelman, R. M. (1988) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910070104 · Cited by 197
Fast and precise T1 imaging using a TOMROP sequence
Brix, G., Schad, L. R., Deimling, M., & Lorenz, W. J. (1990) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(90)90041-y · Cited by 176
Christensen, K. A., Grant, D. M., Schulman, E. M., & Walling, C. (1974) · The Journal of Physical Chemistry · doi:10.1021/j100612a022 · Cited by 175
A fast 3D Look-Locker method for volumetric T1 mapping
Henderson, E., McKinnon, G. C., Lee, T.-Y., & Rutt, B. K. (1999) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(99)00025-9 · Cited by 144
Self-citationHomer, J. B., & Beevers, M. S. (1985) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(85)90318-x · Cited by 138
Dynamic studies of gadolinium uptake in brain tumors using inversion‐recovery echo‐planar imaging
Gowland, P. A., Mansfield, P., Bullock, P. R., Stehling, M. K., Worthington, B. S., & Firth, J. L. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910260206 · Cited by 120
Cited by
Magnetic resonance fingerprinting
Ma, D., Gulani, V., Seiberlich, N., Liu, K., Sunshine, J. L., Duerk, J. L., & Griswold, M. A. (2013) · Nature · doi:10.1038/nature11971 · Cited by 1,577
Deoni, S. C. L., Peters, T. M., & Rutt, B. K. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20314 · Cited by 478
Self-citationFat quantification with IDEAL gradient echo imaging: Correction of bias from T1 and noise
Liu, C., McKenzie, C. A., Yu, H., Brittain, J. H., & Reeder, S. B. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21301 · Cited by 477
Jiang, Y., Ma, D., Seiberlich, N., Gulani, V., & Griswold, M. A. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25559 · Cited by 422
Using high-resolution quantitative mapping of R1 as an index of cortical myelination
Lutti, A., Dick, F., Sereno, M. I., & Weiskopf, N. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.06.005 · Cited by 346
Metadata
- Authors
- Deoni, S. C. L., Rutt, B. K., & Peters, T. M.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2003-03
- Volume
- 49
- Issue
- 3
- Pages
- 515-526
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2019190989
- Cited by
- 744
- References
- 15
- FWCI
- 9.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady state. https://app.cochat.ai/papers/10.1002/mrm.10407
- The paper
- Deoni, S. C. L., Rutt, B. K., & Peters, T. M. (2003). Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady state. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.10407
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.