Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 744

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady state

Deoni, Sean C.L., Rutt, Brian K., Peters, Terry M.·2003·Magnetic Resonance in Medicine

Abstract

A novel, fully 3D, high‐resolution T1 and T2 relaxation time mapping method is presented. The method is based on steady‐state imaging with T1 and T2 information derived from either spoiling or fully refocusing the transverse magnetization following each excitation pulse. T1 is extracted from a pair of spoiled gradient recalled echo (SPGR) images acquired at optimized flip angles. This T1 information is combined with two refocused steady‐state free precession (SSFP) images to determine T2. T1 and T2 accuracy was evaluated against inversion recovery (IR) and spin‐echo (SE) results, respectively. Error within the T1 and T2 maps, determined from both phantom and in vivo measurements, is approximately 7% for T1 between 300 and 2000 ms and 7% for T2 between 30 and 150 ms. The efficiency of the method, defined as the signal‐to‐noise ratio (SNR) of the final map per voxel volume per square root scan time, was evaluated against alternative mapping methods. With an efficiency of three times that of multipoint IR and three times that of multiecho SE, our combined approach represents the most efficient of those examined. Acquisition time for a whole brain T1 map (25 × 25 × 10 cm) is less than 8 min with 1 mm 3 isotropic voxels. An additional 7 min is required for an identically sized T2 map and postprocessing time is less than 1 min on a 1 GHz PIII PC. The method therefore permits real‐time clinical acquisition and display of whole brain T1 and T2 maps for the first time. Magn Reson Med 49:515–526, 2003. © 2003 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.10407

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 15 references

Cited by

See all 744

Metadata

Authors
Deoni, S. C. L., Rutt, B. K., & Peters, T. M.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2003-03
Volume
49
Issue
3
Pages
515-526
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2019190989
Cited by
744
References
15
FWCI
9.05
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady state. https://app.cochat.ai/papers/10.1002/mrm.10407
The paper
Deoni, S. C. L., Rutt, B. K., & Peters, T. M. (2003). Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady state. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.10407

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.