The DOI matches its Crossref record.
Assessment of demyelination, edema, and gliosis by in vivo determination of T1 and T2 in the brain of patients with acute attack of multiple sclerosis
Abstract
This study intended to investigate the possibility of magnetic resonance (MR) to characterize the acute plaque due to multiple sclerosis (MS). To obtain information, in vivo measurements of relaxation processes were performed in 10 patients with known acute MS plaques, using a whole‐body superconductive MR‐scanner, operating at 1.5 T. The measurements were repeated several times, from onset of the disease and during remission by use of six‐point partial saturation inversion recovery and 32‐echo multiple spin‐echo sequences, giving TI and T2, respectively. We also focused on the issue, whether T1 and T2 relaxation processes in fact were monoexponential. The results of the first T1 and T2 measurements of the acute plaques were not clearly different from T1 and T2 of presumably chronic plaques obtained in a group of chronic MS patients previously (H. B. W. Larsson, J. Frederiksen, L. Kjär, O. Hendriksen, and J. Olesen, Magn. Reson. Med. 7, 43 ( 1988)). In some of the acute plaques a slight initial increase in TI and T2 was seen, when the measurement was repeated in about 10 days. Thereafter T1 decreased slowly in all but one patient as a function of days. In all cases the T1 relaxation process followed a monoexponential course. The T2 relaxation process was a monoexponential function in the acute plaques, when measured within 20 days from onset of disease. After an average of 78 days, however, the T2 relaxation process clearly became biexponential in all but two patients. Later some of the relaxation curves changed back toward monoexponentiality. Thus, the study shows that it is possible to detect significant changes in MR parameters during the evolution of the disease, and these changes are discussed in relation to knowledge of pathoanatomical events in MS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Magnetic resonance fingerprinting
Ma, D., Gulani, V., Seiberlich, N., Liu, K., Sunshine, J. L., Duerk, J. L., & Griswold, M. A. (2013) · Nature · doi:10.1038/nature11971 · Cited by 1,577
Deoni, S. C. L., Peters, T. M., & Rutt, B. K. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20314 · Cited by 478
In vivo magnetic resonance diffusion measurement in the brain of patients with multiple sclerosis
Larsson, H. B. W., Thomsen, C., Frederiksen, J., Stubgaard, M., & Henriksen, O. (1992) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(92)90367-9 · Cited by 181
Self-citationStevenson, V. L., Parker, G. J. M., Barker, G. J., Birnie, K., Tofts, P. S., Miller, D. H., & Thompson, A. J. (2000) · Journal of the Neurological Sciences · doi:10.1016/s0022-510x(00)00339-7 · Cited by 126
European Society of Radiology (ESR) (2015) · Insights into Imaging · doi:10.1007/s13244-015-0403-3 · Cited by 59
Metadata
- Authors
- Larsson, H. B. W., Frederiksen, J., Petersen, J., Nordenbo, A., Zeeberg, I., Henriksen, O., & Olesen, J.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1989-09
- Volume
- 11
- Issue
- 3
- Pages
- 337-348
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1974603254
- Cited by
- 158
- References
- 0
- FWCI
- 4.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Assessment of demyelination, edema, and gliosis by in vivo determination of T1 and T2 in the brain of patients with acute attack of multiple sclerosis. https://app.cochat.ai/papers/10.1002/mrm.1910110308
- The paper
- Larsson, H. B. W., Frederiksen, J., Petersen, J., Nordenbo, A., Zeeberg, I., Henriksen, O., & Olesen, J. (1989). Assessment of demyelination, edema, and gliosis by in vivo determination of T1 and T2 in the brain of patients with acute attack of multiple sclerosis. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910110308
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.