Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 178

The DOI matches its Crossref record.

Volume imaging with MR phased arrays

Hayes, Cecil E., Hattes, Neil, Roemer, Peter B.·1991·Magnetic Resonance in Medicine

Abstract

A volume MR phased array was constructed with two coils placed anteriorly and two coils posteriorly. Data acquired simultaneously from the four coils on a phantom were combined into a single image having a signal‐to‐noise ratio 80% better than that from the body coil. Additional comparisons of the four‐coil phased array with a two‐coil phased array and a Helmholtz pair having the same overall dimensions show how variations of signal amplitude and phase in the individual coils affect the composite SNR. Images of the male and female pelvis demonstrate how the improved SNR can be used to reduce the number of excitations, decrease the field of view, increase the echo time, or reduce the slice thickness. © 1991 Academic Press. Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.1910180206

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 178

Metadata

Authors
Hayes, C. E., Hattes, N., & Roemer, P. B.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
1991-04
Volume
18
Issue
2
Pages
309-319
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2020399658
Cited by
178
References
0
FWCI
6.24
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Volume imaging with MR phased arrays. https://app.cochat.ai/papers/10.1002/mrm.1910180206
The paper
Hayes, C. E., Hattes, N., & Roemer, P. B. (1991). Volume imaging with MR phased arrays. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910180206

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.