The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
32‐channel 3 Tesla receive‐only phased‐array head coil with soccer‐ball element geometry
Abstract
A 32‐channel 3T receive‐only phased‐array head coil was developed for human brain imaging. The helmet‐shaped array was designed to closely fit the head with individual overlapping circular elements arranged in patterns of hexagonal and pentagonal symmetry similar to that of a soccer ball. The signal‐to‐noise ratio (SNR) and noise amplification (g‐factor) in accelerated imaging applications were quantitatively evaluated in phantom and human images and compared with commercially available head coils. The 32‐channel coil showed SNR gains of up to 3.5‐fold in the cortex and 1.4‐fold in the corpus callosum compared to a (larger) commercial eight‐channel head coil. The experimentally measured g‐factor performance of the helmet array showed significant improvement compared to the eight‐channel array (peak g‐factor 59% and 26% of the eight‐channel values for four‐ and fivefold acceleration). The performance of the arrays is demonstrated in high‐resolution and highly accelerated brain images. Magn Reson Med, 2006. © 2006 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellus, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,303
Self-citationRoemer, P. B., Edelstein, W. A., Hayes, C. E., Souza, S. P., & Mueller, O. M. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160203 · Cited by 2,322
Theory and application of array coils in MR spectroscopy
Wright, S. M., & Wald, L. L. (1997) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199712)10:8<394::aid-nbm494>3.0.co;2-0 · Cited by 286
Self-citationDesign of a SENSE‐optimized high‐sensitivity MRI receive coil for brain imaging
de Zwart, J. A., Ledden, P. J., Kellman, P., van Gelderen, P., & Duyn, J. H. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10169 · Cited by 192
Specific coil design for SENSE: A six-element cardiac array
Weiger, M., Pruessmann, K. P., Leussler, C. G., R�schmann, P., & Boesiger, P. (2001) · Magnetic Resonance in Medicine · Cited by 183
Volume imaging with MR phased arrays
Hayes, C. E., Hattes, N., & Roemer, P. B. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910180206 · Cited by 178
de Zwart, J. A., Ledden, P. J., van Gelderen, P., Bodurka, J., Chu, R., & Duyn, J. H. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10678 · Cited by 176
64‐channel array coil for single echo acquisition magnetic resonance imaging
McDougall, M. P., & Wright, S. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20568 · Cited by 111
Wang, J., Reykowski, A., & Dickas, J. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.412657 · Cited by 110
Self-citation
Cited by
Multiplexed echo planar imaging for sub-second whole brain FMRI and fast diffusion imaging
Feinberg, D. A., Moeller, S., Smith, S. M., Auerbach, E., Ramanna, S., Glasser, M. F., Miller, K. L., Ugurbil, K., & Yacoub, E. (2010) · PLoS ONE · doi:10.1371/journal.pone.0015710 · Cited by 1,296
Differentiating BOLD and non-BOLD signals in fMRI time series using multi-echo EPI
Kundu, P., Inati, S. J., Evans, J. W., Luh, W.-M., & Bandettini, P. A. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.12.028 · Cited by 615
Quantitative multi-parameter mapping of R1, PD*, MT, and R2* at 3T: a multi-center validation
Weiskopf, N., Suckling, J., Williams, G., Correia, M. M., Inkster, B., Tait, R., Ooi, C., Bullmore, E. T., & Lutti, A. (2013) · Frontiers in Neuroscience · doi:10.3389/fnins.2013.00095 · Cited by 538
Automated segmentation of hippocampal subfields from ultra‐high resolution in vivo MRI
Van Leemput, K., Bakkour, A., Benner, T., Wiggins, G., Wald, L. L., Augustinack, J., Dickerson, B. C., Golland, P., & Fischl, B. (2009) · Hippocampus · doi:10.1002/hipo.20615 · Cited by 405
Self-citationThe future of ultra-high field MRI and fMRI for study of the human brain
Duyn, J. H. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.10.065 · Cited by 261
Metadata
- Authors
- Wiggins, G. C., Triantafyllou, C., Potthast, A., Reykowski, A., Nittka, M., & Wald, L. L.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2006-06-09
- Volume
- 56
- Issue
- 1
- Pages
- 216-223
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2169458841
- Cited by
- 375
- References
- 11
- FWCI
- 11.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 32‐channel 3 Tesla receive‐only phased‐array head coil with soccer‐ball element geometry. https://app.cochat.ai/papers/10.1002/mrm.20925
- The paper
- Wiggins, G. C., Triantafyllou, C., Potthast, A., Reykowski, A., Nittka, M., & Wald, L. L. (2006). 32‐channel 3 Tesla receive‐only phased‐array head coil with soccer‐ball element geometry. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.20925
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.