CoChat

Application of continuous relaxation time distributions to the fitting of data from model systmes and excised tissue

Menon, R. S., Allen, P. S. · 1991 · Magnetic Resonance in Medicine
Cited by 133

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Biological systems exhibit heterogeneity at many different levels, leading to the expectation of multiple relaxation time components for water protons in tissue samples. Traditional methods which fit the relaxation data to an a priori number of discrete components are open to observer bias in their interpretation of this data, and moreover, are intutively less realistic for heterogeneous systems than methods which produce continuous relaxation time distributions. Previous validations of continuous distribution techniques have been made on simulated data assuming uniform Gaussian noise. In the current work we have investigated the ability of one particular linear inverse theory technique to reproduce known relaxation time distributions from the data on a controllable model system. Furthermore, using the experience gained on the model system, we have applied this same technique to the analysis of in vitro relaxation time measurements on excised brain tissue and found for water protons in white matter, four reproducible components for the transverse relaxation, whereas gray matter gave rise to only two. The lougitudinal relaxation displayed only one component in either white matter or gray matter. © 1991 Academic Press, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.1910200205

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 133

Metadata

Authors
Menon, R. S., & Allen, P. S.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
1991-08
Volume
20
Issue
2
Pages
214-227
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2002427583
Cited by
133
References
2
FWCI
4.58
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.