The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Perfusion imaging
Abstract
Measurement of tissue perfusion is important for the functional assessment of organs in vivo. Here we report the use of 1 H NMR imaging to generate perfusion maps in the rat brain at 4.7 T. Blood water flowing to the brain is saturated in the neck region with a sliceselective saturation imaging sequence, creating an endogenous tracer in the form of proximally saturated spins. Because proton T 1 times are relatively long, particularly at high field strengths, saturated spins exchange with bulk water in the brain and a steady state is created where the regional concentration of saturated spins is determined by the regional blood flow and regional T 1. Distal saturation applied equidistantly outside the brain serves as a control for effects of the saturation pulses. Average cerebral blood flow in normocapnic rat brain under halothane anesthesia was determined to be 105 ± 16 cc. 100 g−1. min−1 (mean ± SEM, n = 3), in good agreement with values reported in the literature, and was sensitive to increases in arterial p CO 2. This technique allows regional perfusion maps to be measured noninvasively, with the resolution of 1 H MRI, and should be readily applicable to human studies. © 1992 Academic Press, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Magnetization transfer contrast (MTC) and tissue water proton relaxation in vivo
Wolff, S. D., & Balaban, R. S. (1989) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910100113 · Cited by 1,482
What is the Correct Value for the Brain-Blood Partition Coefficient for Water?
Herscovitch, P., & Raichle, M. E. (1985) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1985.9 · Cited by 705
Functional cerebral imaging by susceptibility‐contrast NMR
Belliveau, J. W., Rosen, B. R., Kantor, H. L., Rzedzian, R. R., Kennedy, D. N., McKinstry, R. C., Vevea, J. M., Cohen, M. S., Pykett, I. L., & Brady, T. J. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140311 · Cited by 570
Brooker, H. R. (1983) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(83)90089-6 · Cited by 455
Projection angiograms of blood labeled by adiabatic fast passage
Dixon, W. T., Du, L. N., Faul, D. D., Gado, M., & Rossnick, S. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030311 · Cited by 282
Baron, J. C., Frackowiak, R. S. J., Herholz, K., Jones, T., Lammertsma, A. A., Mazoyer, B., & Wienhard, K. (1989) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1989.105 · Cited by 168
Blood Flow and Metabolic Rate for Oxygen in the Cerebral Cortex of the Rat
Eklöf, B., Lassen, N. A., Nilsson, L., Norberg, K. A., & Siesjö, B. K. (1973) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1973.tb05489.x · Cited by 129
Cerebral Blood Flow: Physiologic and clinical Aspects
Gewertz, B. L. (1988) · Annals of Vascular Surgery · doi:10.1016/s0890-5096(06)60788-7 · Cited by 110
Measurement of regional cerebral blood flow in cat brain using intracarotid 2H2O and 2H NMR imaging
Detre, J. A., Subramanian, V. H., Mitchell, M. D., Smith, D. S., Kobayashi, A., Zaman, A., & Leigh, J. S. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140223 · Cited by 65
Self-citationJones, S. C., Greenberg, J. H., & Reivich, M. (1982) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198202000-00020 · Cited by 62
Cited by
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212
Alsop, D. C., Detre, J. A., Golay, X., Günther, M., Hendrikse, J., Hernandez‐Garcia, L., Lu, H., MacIntosh, B. J., Parkes, L. M., Smits, M., et al. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25197 · Cited by 2,206
Self-citationNeurocognitive consequences of sleep deprivation
Goel, N., Rao, H., Durmer, J., & Dinges, D. (2009) · Seminars in Neurology · doi:10.1055/s-0029-1237117 · Cited by 2,154
A general kinetic model for quantitative perfusion imaging with arterial spin labeling
Buxton, R. B., Frank, L. R., Wong, E. C., Siewert, B., Warach, S., & Edelman, R. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400308 · Cited by 1,263
Overview of Functional Magnetic Resonance Imaging
Glover, G. H. (2011) · Neurosurgery Clinics of North America · doi:10.1016/j.nec.2010.11.001 · Cited by 1,024
Kim, S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340303 · Cited by 1,001
Dai, W., Garcia, D., de Bazelaire, C., & Alsop, D. C. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21790 · Cited by 985
Østergaard, L., Sorensen, A. G., Kwong, K. K., Weisskoff, R. M., Gyldensted, C., & Rosen, B. R. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360511 · Cited by 810
Patton, N., Aslam, T., MacGillivray, T., Pattie, A., Deary, I. J., & Dhillon, B. (2005) · Journal of Anatomy · doi:10.1111/j.1469-7580.2005.00395.x · Cited by 807
Alsop, D. C., & Detre, J. A. (1996) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199611000-00019 · Cited by 754
Self-citationRapid combined T1 and T2 mapping using gradient recalled acquisition in the steady state
Deoni, S. C. L., Rutt, B. K., & Peters, T. M. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10407 · Cited by 744
Quantitative imaging of perfusion using a single subtraction (QUIPSS and QUIPSS II)
Wong, E. C., Buxton, R. B., & Frank, L. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390506 · Cited by 689
Determining the longitudinal relaxation time (T1) of blood at 3.0 Tesla
Lu, H., Clingman, C., Golay, X., & van Zijl, P. C. M. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20178 · Cited by 685
Toussaint, J.-F., LaMuraglia, G. M., Southern, J. F., Fuster, V., & Kantor, H. L. (1996) · Circulation · doi:10.1161/01.cir.94.5.932 · Cited by 668
Measuring Cerebral Blood Flow Using Magnetic Resonance Imaging Techniques
Calamante, F., Thomas, D. L., Pell, G. S., Wiersma, J., & Turner, R. (1999) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199907000-00001 · Cited by 638
Glial Neoplasms: Dynamic Contrast-enhanced T2*-weighted MR Imaging
Knopp, E. A., Cha, S., Johnson, G., Mazumdar, A., Golfinos, J. G., Zagzag, D., Miller, D. C., Kelly, P. J., & Kricheff, I. I. (1999) · Radiology · doi:10.1148/radiology.211.3.r99jn46791 · Cited by 596
Comparative Overview of Brain Perfusion Imaging Techniques
Wintermark, M., Sesay, M., Barbier, E., Borbély, K., Dillon, W. P., Eastwood, J. D., Glenn, T. C., Grandin, C. B., Pedraza, S., Soustiel, J.-F., et al. (2005) · Stroke · doi:10.1161/01.str.0000177884.72657.8b · Cited by 592
Harms, M. P., Somerville, L. H., Ances, B. M., Andersson, J., Barch, D. M., Bastiani, M., Bookheimer, S. Y., Brown, T. B., Buckner, R. L., Burgess, G. C., et al. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.09.060 · Cited by 584
Biophysical and Physiological Origins of Blood Oxygenation Level-Dependent fMRI Signals
Kim, S.-G., & Ogawa, S. (2012) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2012.23 · Cited by 547
Dynamic functional imaging of relative cerebral blood volume during rat forepaw stimulation
Mandeville, J. B., Marota, J. J. A., Kosofsky, B. E., Keltner, J. R., Weissleder, R., Rosen, B. R., & Weisskoff, R. M. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390415 · Cited by 549
Event-related functional MRI: Past, present, and future
Rosen, B. R., Buckner, R. L., & Dale, A. M. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.3.773 · Cited by 526
Cha, S., Knopp, E. A., Johnson, G., Wetzel, S. G., Litt, A. W., & Zagzag, D. (2002) · Radiology · doi:10.1148/radiol.2231010594 · Cited by 525
Arterial Spin Labeling Perfusion of the Brain: Emerging Clinical Applications
Haller, S., Zaharchuk, G., Thomas, D. L., Lovblad, K.-O., Barkhof, F., & Golay, X. (2016) · Radiology · doi:10.1148/radiol.2016150789 · Cited by 514
Luh, W.-M., Wong, E. C., Bandettini, P. A., & Hyde, J. S. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199906)41:6<1246::aid-mrm22>3.0.co;2-n · Cited by 506
Chalela, J. A., Alsop, D. C., Gonzalez-Atavales, J. B., Maldjian, J. A., Kasner, S. E., & Detre, J. A. (2000) · Stroke · doi:10.1161/01.str.31.3.680 · Cited by 481
Self-citationMr perfusion studies with t1‐weighted echo planar imaging
Kwong, K. K., Chesler, D. A., Weisskoff, R. M., Donahue, K. M., Davis, T. L., Ostergaard, L., Campbell, T. A., & Rosen, B. R. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340613 · Cited by 477
Empirical optimization of ASL data analysis using an ASL data processing toolbox: ASLtbx
Wang, Z., Aguirre, G. K., Rao, H., Wang, J., Fernández-Seara, M. A., Childress, A. R., & Detre, J. A. (2008) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2007.07.003 · Cited by 477
Self-citationWu, W., Fernández‐Seara, M., Detre, J. A., Wehrli, F. W., & Wang, J. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21403 · Cited by 465
Self-citationCalamante, F., Gadian, D. G., & Connelly, A. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200009)44:3<466::aid-mrm18>3.0.co;2-m · Cited by 458
Assessment of cerebral blood flow in Alzheimer's disease by spin-labeled magnetic resonance imaging
Alsop, D. C., Detre, J. A., & Grossman, M. (2000) · Annals of Neurology · doi:10.1002/1531-8249(200001)47:1<93::aid-ana15>3.0.co;2-8 · Cited by 409
Self-citationMethodology of brain perfusion imaging
Barbier, E. L., Lamalle, L., & Décorps, M. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1073 · Cited by 404
Circadian rhythms, sleep deprivation, and human performance
Goel, N., Basner, M., Rao, H., & Dinges, D. F. (2013) · Progress in Molecular Biology and Translational Science · doi:10.1016/b978-0-12-396971-2.00007-5 · Cited by 400
Fantini, S., Sassaroli, A., Tgavalekos, K. T., & Kornbluth, J. (2016) · Neurophotonics · doi:10.1117/1.nph.3.3.031411 · Cited by 397
Comparison of quantitative perfusion imaging using arterial spin labeling at 1.5 and 4.0 Tesla
Wang, J., Alsop, D. C., Li, L., Listerud, J., Gonzalez‐At, J. B., Schnall, M. D., & Detre, J. A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10211 · Cited by 369
Self-citationEffects of transcranial direct current stimulation (tDCS) on human regional cerebral blood flow
Zheng, X., Alsop, D. C., & Schlaug, G. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.06.018 · Cited by 368
Somerville, L. H., Bookheimer, S. Y., Buckner, R. L., Burgess, G. C., Curtiss, S. W., Dapretto, M., Elam, J. S., Gaffrey, M. S., Harms, M. P., Hodge, C., et al. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.08.050 · Cited by 366
Franklin, T. R., wang, Z., Wang, J., Sciortino, N., Harper, D., Li, Y., Ehrman, R., Kampman, K., O'Brien, C. P., Detre, J. A., et al. (2007) · Neuropsychopharmacology · doi:10.1038/sj.npp.1301371 · Cited by 358
Self-citationNon-invasive measurement of perfusion: a critical review of arterial spin labelling techniques
Petersen, E. T., Zimine, I., Ho, Y.-C. L., & Golay, X. (2006) · The British Journal of Radiology · doi:10.1259/bjr/67705974 · Cited by 352
ON THE CHARACTERISTICS OF FUNCTIONAL MAGNETIC RESONANCE IMAGING OF THE BRAIN
Ogawa, S., Menon, R. S., Kim, S.-G., & Ugurbil, K. (1998) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.27.1.447 · Cited by 343
Localized cerebral blood flow response at submillimeter columnar resolution
Duong, T. Q., Kim, D.-S., Uğurbil, K., & Kim, S.-G. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.191101098 · Cited by 342
The physics of functional magnetic resonance imaging (fMRI)
Buxton, R. B. (2013) · Reports on Progress in Physics · doi:10.1088/0034-4885/76/9/096601 · Cited by 341
Tissue specific perfusion imaging using arterial spin labeling
Detre, J. A., Zhang, W., Roberts, D. A., Silva, A. C., Williams, D. S., Grandis, D. J., Koretsky, A. P., & Leigh, J. S. (1994) · NMR in Biomedicine · doi:10.1002/nbm.1940070112 · Cited by 335
Self-citationApplications of arterial spin labeled MRI in the brain
Detre, J. A., Rao, H., Wang, D. J. J., Chen, Y. F., & Wang, Z. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23581 · Cited by 326
Self-citationYe, F. Q., Berman, K. F., Ellmore, T., Esposito, G., van Horn, J. D., Yang, Y., Duyn, J., Smith, A. M., Frank, J. A., Weinberger, D. R., et al. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200009)44:3<450::aid-mrm16>3.0.co;2-0 · Cited by 317
Analysis of task-based functional MRI data preprocessed with fMRIPrep
Esteban, O., Ciric, R., Finc, K., Blair, R. W., Markiewicz, C. J., Moodie, C. A., Kent, J. D., Goncalves, M., DuPre, E., Gomez, D. E. P., et al. (2020) · Nature Protocols · doi:10.1038/s41596-020-0327-3 · Cited by 315
Ye, F. Q., Frank, J. A., Weinberger, D. R., & McLaughlin, A. C. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200007)44:1<92::aid-mrm14>3.0.co;2-m · Cited by 309
Detre, J. A., & Alsop, D. C. (1999) · European Journal of Radiology · doi:10.1016/s0720-048x(99)00050-9 · Cited by 299
Self-citationMulti-parametric neuroimaging reproducibility: A 3-T resource study
Landman, B. A., Huang, A. J., Gifford, A., Vikram, D. S., Lim, I. A. L., Farrell, J. A. D., Bogovic, J. A., Hua, J., Chen, M., Jarso, S., et al. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.11.047 · Cited by 299
A neuroradiologist’s guide to arterial spin labeling MRI in clinical practice
Grade, M., Hernandez Tamames, J. A., Pizzini, F. B., Achten, E., Golay, X., & Smits, M. (2015) · Neuroradiology · doi:10.1007/s00234-015-1571-z · Cited by 298
Arterial Spin-Labeling in Routine Clinical Practice, Part 1: Technique and Artifacts
Deibler, A. R., Pollock, J. M., Kraft, R. A., Tan, H., Burdette, J. H., & Maldjian, J. A. (2008) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1030 · Cited by 298
Ye, F. Q., Mattay, V. S., Jezzard, P., Frank, J. A., Weinberger, D. R., & McLaughlin, A. C. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370215 · Cited by 294
Technical aspects and utility of fMRI using BOLD and ASL
Detre, J. A., & Wang, J. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00038-x · Cited by 291
Self-citationHata, R., Mies, G., Wiessner, C., Fritze, K., Hesselbarth, D., Brinker, G., & Hossmann, K.-A. (1998) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199804000-00004 · Cited by 280
Wang, J., Zhang, Y., Wolf, R. L., Roc, A. C., Alsop, D. C., & Detre, J. A. (2005) · Radiology · doi:10.1148/radiol.2351031663 · Cited by 271
Self-citationSicard, K., Shen, Q., Brevard, M. E., Sullivan, R., Ferris, C. F., King, J. A., & Duong, T. Q. (2003) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200304000-00011 · Cited by 263
Floyd, T. F., Clark, J. M., Gelfand, R., Detre, J. A., Ratcliffe, S., Guvakov, D., Lambertsen, C. J., & Eckenhoff, R. G. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00303.2003 · Cited by 258
Self-citationChen, Y. C. I., Galpern, W. R., Brownell, A., Matthews, R. T., Bogdanov, M., Isacson, O., Keltner, J. R., Beal, M. F., Rosen, B. R., & Jenkins, B. G. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380306 · Cited by 257
Perfusion Magnetic Resonance Imaging: A Comprehensive Update on Principles and Techniques
Jahng, G.-H., Li, K.-L., Ostergaard, L., & Calamante, F. (2014) · Korean Journal of Radiology · doi:10.3348/kjr.2014.15.5.554 · Cited by 256
Neural substrates of abstinence-induced cigarette cravings in chronic smokers
Wang, Z., Faith, M., Patterson, F., Tang, K., Kerrin, K., Wileyto, E. P., Detre, J. A., & Lerman, C. (2007) · The Journal of Neuroscience · doi:10.1523/jneurosci.2966-07.2007 · Cited by 256
Self-citationDuong, T. Q., Silva, A. C., Lee, S.-P., & Kim, S.-G. (2000) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(200003)43:3<383::aid-mrm10>3.0.co;2-q · Cited by 254
Ultrahigh field magnetic resonance imaging and spectroscopy
Uğurbil, K., Adriany, G., Andersen, P., Chen, W., Garwood, M., Gruetter, R., Henry, P.-G., Kim, S.-G., Lieu, H., Tkac, I., et al. (2003) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2003.08.027 · Cited by 252
Paloyelis, Y., Doyle, O. M., Zelaya, F. O., Maltezos, S., Williams, S. C., Fotopoulou, A., & Howard, M. A. (2016) · Biological Psychiatry · doi:10.1016/j.biopsych.2014.10.005 · Cited by 187
Wolk (2012) · doi:10.1097/wco.0b013e328354ff0a · Cited by 147
Improved Reperfusion and Neuroprotection by Creatine in a Mouse Model of Stroke
Prass, K., Royl, G., Lindauer, U., Freyer, D., Megow, D., Dirnagl, U., Stöckler-Ipsiroglu, G., Wallimann, T., & Priller, J. (2007) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/sj.jcbfm.9600351 · Cited by 128
Neural effects of short-term training on working memory
Buschkuehl, M., Hernandez-Garcia, L., Jaeggi, S. M., Bernard, J. A., & Jonides, J. (2014) · Cognitive, Affective, & Behavioral Neuroscience · doi:10.3758/s13415-013-0244-9 · Cited by 117
Tarumi, T., Shah, F., Tanaka, H., & Haley, A. P. (2011) · American Journal of Hypertension · doi:10.1038/ajh.2011.101 · Cited by 108
Lawrence, K. S., Frank, J. A., & McLaughlin, A. C. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200009)44:3<440::aid-mrm15>3.0.co;2-6 · Cited by 108
Pfefferbaum, A., Chanraud, S., Pitel, A.-L., Muller-Oehring, E., Shankaranarayanan, A., Alsop, D. C., Rohlfing, T., & Sullivan, E. V. (2011) · Cerebral Cortex · doi:10.1093/cercor/bhq090 · Cited by 104
Physiological noise reduction for arterial spin labeling functional MRI
Restom, K., Behzadi, Y., & Liu, T. T. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.01.026 · Cited by 101
Bron, E. E., Steketee, R. M. E., Houston, G. C., Oliver, R. A., Achterberg, H. C., Loog, M., van Swieten, J. C., Hammers, A., Niessen, W. J., Smits, M., et al. (2014) · Human Brain Mapping · doi:10.1002/hbm.22522 · Cited by 93
Amygdala Hyperactivity at Rest in Paranoid Individuals With Schizophrenia
Pinkham, A. E., Liu, P., Lu, H., Kriegsman, M., Simpson, C., & Tamminga, C. (2015) · American Journal of Psychiatry · doi:10.1176/appi.ajp.2014.14081000 · Cited by 93
Bron, E. E., Smits, M., Papma, J. M., Steketee, R. M. E., Meijboom, R., de Groot, M., van Swieten, J. C., Niessen, W. J., & Klein, S. (2017) · European Radiology · doi:10.1007/s00330-016-4691-x · Cited by 84
Yang, Y., Gu, H., Zhan, W., Xu, S., Silbersweig, D. A., & Stern, E. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10196 · Cited by 77
Estimation of perfusion properties with MR fingerprinting arterial spin labeling
Wright, K. L., Jiang, Y., Ma, D., Noll, D. C., Griswold, M. A., Gulani, V., & Hernandez-Garcia, L. (2018) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2018.03.011 · Cited by 51
Liang, X., Connelly, A., & Calamante, F. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.11.013 · Cited by 48
Bartelle, B. B., Barandov, A., & Jasanoff, A. (2016) · The Journal of Neuroscience · doi:10.1523/jneurosci.4050-15.2016 · Cited by 45
Pseudocontinuous arterial spin labeling with optimized tagging efficiency
Shin, D. D., Liu, T. T., Wong, E. C., Shankaranarayanan, A., & Jung, Y. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24113 · Cited by 37
Hussein, R., Shin, D., Zhao, M. Y., Guo, J., Davidzon, G., Steinberg, G., Moseley, M., & Zaharchuk, G. (2024) · Medical Image Analysis · doi:10.1016/j.media.2023.103072 · Cited by 9
Inducing Paranoia is Linked to Increased Resting Amygdala Cerebral Blood Flow in Healthy Individuals
Pinkham, A., Bass, E., Klein, H., Springfield, C., Kent, J., & Aslan, S. (2022) · Journal of Experimental Psychopathology · doi:10.1177/20438087221130693 · Cited by 8
Metadata
- Authors
- Detre, J. A., Leigh, J. S., Williams, D. S., & Koretsky, A. P.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1992-01
- Volume
- 23
- Issue
- 1
- Pages
- 37-45
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W4233867216
- Cited by
- 1,571
- References
- 11
- FWCI
- 19.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.