The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Diffusion Weighting by the Trace of the Diffusion Tensor within a Single Scan
Abstract
The anisotropy of the water diffusion tensor inside brain causes contrast in diffusion images, which depends on the relative orientation of the diffusion gradients and the subject. Because the trace of a tensor is invariant upon rotation, measurement of this trace can reduce the orientation effect. A family of imaging pulse sequences is presented in which the signal intensity is weighted by the trace of the diffusion tensor in a single scan. The methods are demonstrated for chicken gizzard in several orientations with respect to the gradient frame of reference, and for ischemic injury in cat brain after middle cerebral artery occlusion. The sensitivity of the techniques to the presence of background gradients is measured and discussed in detail. As a result, pulse sequences are suggested that provide reliable diffusion constants in both homogeneous and inhomogeneous magnetic fields. The efficiency of the techniques for clinical application is also evaluated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Le Bihan, D., Breton, E., Lallemand, D., Grenier, P., Cabanis, E., & Laval-Jeantet, M. (1986) · Radiology · doi:10.1148/radiology.161.2.3763909 · Cited by 3,912
Cited by
The basis of anisotropic water diffusion in the nervous system—A technical review.
Beaulieu, C. (2002) · NMR in Biomedicine · doi:10.1002/nbm.782 · Cited by 4,628
Diffusion tensor imaging: Concepts and applications
Le Bihan, D., Mangin, J., Poupon, C., Clark, C. A., Pappata, S., Molko, N., & Chabriat, H. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1076 · Cited by 3,547
The basics of brain development
Stiles, J., & Jernigan, T. L. (2010) · Neuropsychology Review · doi:10.1007/s11065-010-9148-4 · Cited by 2,009
Quantifying brain microstructure with diffusion MRI: Theory and parameter estimation
Novikov, D. S., Fieremans, E., Jespersen, S. N., & Kiselev, V. G. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3998 · Cited by 581
Molecular diffusion, tissue microdynamics and microstructure
Bihan, D. L. (1995) · NMR in Biomedicine · doi:10.1002/nbm.1940080711 · Cited by 497
Metadata
- Authors
- Mori, S., & Van Zijl, P. C. M.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1995-01
- Volume
- 33
- Issue
- 1
- Pages
- 41-52
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1975528228
- Cited by
- 278
- References
- 1
- FWCI
- 12.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diffusion Weighting by the Trace of the Diffusion Tensor within a Single Scan. https://app.cochat.ai/papers/10.1002/mrm.1910330107
- The paper
- Mori, S., & Van Zijl, P. C. M. (1995). Diffusion Weighting by the Trace of the Diffusion Tensor within a Single Scan. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910330107
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.