The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Real‐Time Functional Magnetic Resonance Imaging
Abstract
A recursive algorithm suitable for functional magnetic resonance imaging (FMRI) calculations is presented. The correlation coefficient of a time course of images with a reference time series, with the mean and any linear trend projected out, may be computed with 22 operations per voxel, per image; the storage overhead is four numbers per voxel. A statistical model for the FMRI signal is presented, and thresholds for the correlation coefficient are derived from it. Selected images from the first real‐time functional neuroimaging experiment (at 3 Tesla) are presented. Using a 50‐MHz workstation equipped with a 14‐bit analog‐to‐digital converter, each echo planar image was acquired, reconstructed, correlated, thresh‐olded, and displayed in pseudocolor (highlighting active regions in the brain) within 500 ms of the RF pulse.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Handbook of Mathematical Functions
McQuarrie, D. A. (1966) · American Journal of Physics · doi:10.1119/1.1972842 · Cited by 40,433
Brain magnetic resonance imaging with contrast dependent on blood oxygenation.
Ogawa, S., Lee, T. M., Kay, A. R., & Tank, D. W. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.24.9868 · Cited by 6,483
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212
Time course EPI of human brain function during task activation
Bandettini, P. A., Wong, E. C., Hinks, R. S., Tikofsky, R. S., & Hyde, J. S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250220 · Cited by 1,935
Self-citationFunctional mapping of the human visual cortex by magnetic resonance imaging
Belliveau, J. W., Kennedy, D. N., McKinstry, R. C., Buchbinder, B. R., Weisskoff, R. M., Cohen, M. S., Vevea, J. M., Brady, T. J., & Rosen, B. R. (1991) · Science · doi:10.1126/science.1948051 · Cited by 1,883
Cited by
Software tools for analysis and visualization of fMRI data
Cox, R. W., & Hyde, J. S. (1997) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199706/08)10:4/5<171::aid-nbm453>3.0.co;2-l · Cited by 1,352
Self-citationHarnessing neuroplasticity for clinical applications
Cramer, S. C., Sur, M., Dobkin, B. H., O'Brien, C., Sanger, T. D., Trojanowski, J. Q., Rumsey, J. M., Hicks, R., Cameron, J., Chen, D., et al. (2011) · Brain · doi:10.1093/brain/awr039 · Cited by 1,259
Control over brain activation and pain learned by using real-time functional MRI
deCharms, R. C., Maeda, F., Glover, G. H., Ludlow, D., Pauly, J. M., Soneji, D., Gabrieli, J. D. E., & Mackey, S. C. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0505210102 · Cited by 876
Real-time 3D image registration for functional MRI
Cox, R. W., & Jesmanowicz, A. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199912)42:6<1014::aid-mrm4>3.0.co;2-f · Cited by 663
Self-citationBrain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
Metadata
- Authors
- Cox, R. W., Jesmanowicz, A., & Hyde, J. S.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1995-02
- Volume
- 33
- Issue
- 2
- Pages
- 230-236
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2053428045
- Cited by
- 316
- References
- 5
- FWCI
- 8.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Real‐Time Functional Magnetic Resonance Imaging. https://app.cochat.ai/papers/10.1002/mrm.1910330213
- The paper
- Cox, R. W., Jesmanowicz, A., & Hyde, J. S. (1995). Real‐Time Functional Magnetic Resonance Imaging. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910330213
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.