The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Respiratory Motion of the Heart: Kinematics and the Implications for the Spatial Resolution in Coronary Imaging
Abstract
Respiratory motion is a major limiting factor in improving image resolution and signal‐to‐noise ratio in MR coronary imaging. In this work the effects of respiration on the cardiac position were studied quantitively by imaging the heart during diastole at various positions of tidal respiration with a breath‐hold segmented fast gradient echo technique. It was found that during tidal breathing the movement of the heart due to respiration is dominated by superior‐inferior (SI) motion, which is linearly related to the SI motion of the diaphragm. The motion of the heart due to respiration is approximately a global translation. These results provide motivation for employing adaptive motion correction techniques to reduce image blurring in nonbreath‐hold coronary MR imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adaptive technique for high-definition MR imaging of moving structures.
Ehman, R. L., & Felmlee, J. P. (1989) · Radiology · doi:10.1148/radiology.173.1.2781017 · Cited by 801
Self-citationCoronary arteries: breath-hold MR angiography.
Edelman, R. R., Manning, W. J., Burstein, D., & Paulin, S. (1991) · Radiology · doi:10.1148/radiology.181.3.1947074 · Cited by 361
Magnetic resonance imaging with respiratory gating: techniques and advantages
Ehman, R., McNamara, M., Pallack, M., Hricak, H., & Higgins, C. (1984) · American Journal of Roentgenology · doi:10.2214/ajr.143.6.1175 · Cited by 299
Self-citationLi, D., Paschal, C. B., Haacke, E. M., & Adler, L. P. (1993) · Radiology · doi:10.1148/radiology.187.2.8475281 · Cited by 224
MRI of coronary arteries: 2D breath-hold vs 3D respiratory-gated acquisition.
Hofman, M. B., Paschal, C. B., Li, D., et al. (1995) · PubMed · Cited by 115
Cited by
Markl, M., Frydrychowicz, A., Kozerke, S., Hope, M., & Wieben, O. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23632 · Cited by 788
Motion artifacts in MRI: A complex problem with many partial solutions
Zaitsev, M., Maclaren, J., & Herbst, M. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24850 · Cited by 774
Improved Coronary Artery Definition With T2-Weighted, Free-Breathing, Three-Dimensional Coronary MRA
Botnar, R. M., Stuber, M., Danias, P. G., Kissinger, K. V., & Manning, W. J. (1999) · Circulation · doi:10.1161/01.cir.99.24.3139 · Cited by 425
Development of a 4-D digital mouse phantom for molecular imaging research
SEGARS, W. (2004) · Molecular Imaging & Biology · doi:10.1016/j.mibio.2004.03.002 · Cited by 420
Respiratory motion models: A review
McClelland, J. R., Hawkes, D. J., Schaeffter, T., & King, A. P. (2013) · Medical Image Analysis · doi:10.1016/j.media.2012.09.005 · Cited by 385
Metadata
- Authors
- Wang, Y., Riederer, S. J., & Ehman, R. L.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1995-05
- Volume
- 33
- Issue
- 5
- Pages
- 713-719
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1994587523
- Cited by
- 491
- References
- 5
- FWCI
- 9.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.