The DOI matches its Crossref record.
Coronary arteries: three-dimensional MR imaging with fat saturation and magnetization transfer contrast.
Abstract
Magnetic resonance imaging of the coronary arteries is a particularly difficult task because of the small size of the vessels and the motion of the heart during the cardiac and respiratory cycles. The authors developed a non-breath-hold three-dimensional (3D) technique to accomplish this goal. Imaging was performed with voxel sizes of 1.50-4.50 mm3. This allows for excellent multiplanar reconstruction to view the coronary arteries from any angle. The short echo time usually makes blood isointense with surrounding tissue since inflow enhancement is weak with a thick-slab 3D method. This problem is overcome by applying fat saturation and magnetization transfer contrast techniques to suppress the signals of fat and myocardium surrounding the coronary arteries. Respiratory motion artifacts are reduced by taking four acquisitions and averaging the data. The authors acquired the first 3-10 cm of both the left and right coronary arteries in most cases in 7-10 minutes with single slab coverage. Acquisition of multiple slabs should further increase the length of coverage of the coronary arteries. Further improvements will occur when respiratory gating is used.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wang, Y., Riederer, S. J., & Ehman, R. L. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330517 · Cited by 491
Bluemke, D. A., Achenbach, S., Budoff, M., Gerber, T. C., Gersh, B., Hillis, L. D., Hundley, W. G., Manning, W. J., Printz, B. F., Stuber, M., et al. (2008) · Circulation · doi:10.1161/circulationaha.108.189695 · Cited by 461
Coronary Angiography with Magnetization‐Prepared T2 Contrast
Brittain, J. H., Hu, B. S., Wright, G. A., Meyer, C. H., Macovski, A., & Nishimura, D. G. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330515 · Cited by 448
Improved Coronary Artery Definition With T2-Weighted, Free-Breathing, Three-Dimensional Coronary MRA
Botnar, R. M., Stuber, M., Danias, P. G., Kissinger, K. V., & Manning, W. J. (1999) · Circulation · doi:10.1161/01.cir.99.24.3139 · Cited by 425
Post, J. C., van Rossum, A. C., Bronzwaer, J. G. F., de Cock, C. C., Hofman, M. B. M., Valk, J., & Visser, C. A. (1995) · Circulation · doi:10.1161/01.cir.92.11.3163 · Cited by 339
Metadata
- Authors
- Li, D., Paschal, C. B., Haacke, E. M., & Adler, L. P.
- Venue
- Radiology
- Published
- 1993-05
- Volume
- 187
- Issue
- 2
- Pages
- 401-406
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2024949718
- Cited by
- 224
- References
- 0
- FWCI
- 14.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Coronary arteries: three-dimensional MR imaging with fat saturation and magnetization transfer contrast. https://app.cochat.ai/papers/10.1148/radiology.187.2.8475281
- The paper
- Li, D., Paschal, C. B., Haacke, E. M., & Adler, L. P. (1993). Coronary arteries: three-dimensional MR imaging with fat saturation and magnetization transfer contrast. Radiology. https://doi.org/10.1148/radiology.187.2.8475281
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.