The DOI matches its Crossref record.
Theory of 1/T1 and 1/T2 NMRD profiles of solutions of magnetic nanoparticles
Abstract
Organically coated iron oxide crystallites with diameters of 5–50 nm (“nanoparticles”) are potential magnetic resonance imaging contrast agents. 1/T1 and 1/T2 of solvent water protons are increased dramatically by magnetic interactions in the “outer sphere” environment of the nanoparticles; subsequent diffusive mixing distributes this relaxation throughout the solvent. Published theory, valid for the solute magnetic energy small compared with thermal energy, is applicable to small magnetic solutes (e.g., gadolinium and manganese diethylenetriaminopentaacetic acid, and nitroxide free radicals) at generally accessible fields (≤ 50 T). It fails for nanoparticles at fields above ˜0.05 T, i.e., at most imaging fields. The authors have reformulated outer sphere relaxation theory to incorporate progressive magnetic saturation of solute nanoparticles and, in addition, indicate how to use empirical magnetization data for realistic particles when their magnetic properties are not ideal. It is important to handle the effects of rapid thermally induced reorientation of the magnetization of the nanoparticles (their “superparamagnetism”) effectively, including their sensitivity to particle size. The theoretical results are presented as the magnetic field dependence (NMRD profiles) of 1/T1 and 1/T2, normalized to Fe content, for three sizes of particles, and then compared with the limited data extant for well‐characterized material.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Laurent, S., Forge, D., Port, M., Roch, A., Robic, C., Vander Elst, L., & Muller, R. N. (2008) · Chemical Reviews · doi:10.1021/cr068445e · Cited by 6,852
Artificially engineered magnetic nanoparticles for ultra-sensitive molecular imaging
Lee, J.-H., Huh, Y.-M., Jun, Y.-W., Seo, J.-W., Jang, J.-T., Song, H.-T., Kim, S., Cho, E.-J., Yoon, H.-G., Suh, J.-S., et al. (2007) · Nature Medicine · doi:10.1038/nm1467 · Cited by 1,897
Nanoscaling Laws of Magnetic Nanoparticles and Their Applicabilities in Biomedical Sciences
Jun, Y.-W., Seo, J.-W., & Cheon, J. (2008) · Accounts of Chemical Research · doi:10.1021/ar700121f · Cited by 872
Magnetite-loaded polymeric micelles as ultrasensitive magnetic-resonance probes
Ai, H., Flask, C., Weinberg, B., Shuai, X. ‐., Pagel, M. D., Farrell, D., Duerk, J., & Gao, J. (2005) · Advanced Materials · doi:10.1002/adma.200401904 · Cited by 465
Smolensky, E. D., Park, H.-Y. E., Zhou, Y., Rolla, G. A., Marjańska, M., Botta, M., & Pierre, V. C. (2013) · Journal of Materials Chemistry B · doi:10.1039/c3tb00369h · Cited by 156
Metadata
- Authors
- Koenig, S. H., & Kellar, K. E.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1995-08
- Volume
- 34
- Issue
- 2
- Pages
- 227-233
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2171442859
- Cited by
- 314
- References
- 0
- FWCI
- 5.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Theory of 1/T1 and 1/T2 NMRD profiles of solutions of magnetic nanoparticles. https://app.cochat.ai/papers/10.1002/mrm.1910340214
- The paper
- Koenig, S. H., & Kellar, K. E. (1995). Theory of 1/T1 and 1/T2 NMRD profiles of solutions of magnetic nanoparticles. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910340214
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.