CoChat

High resolution quantitative relaxation and diffusion mri of three different experimental brain tumors in rat

Eis, Manfred, Els, Thomas, Hoehn‐Berlage, Mathias · 1995 · Magnetic Resonance in Medicine
Cited by 122

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

The potential of quantitative parameter images of the relaxation times T1 and T2, the proton density p and the apparent diffusion coefficient (ADC) to characterize three different experimental rat brain tumors (F98 glioma, RN6 Schwannoma, and E376 neuroblastoma) was studied. All parameter values, as determined in histologically confirmed regions of interest (ROI), were higher in edema than in tumor, which in turn were elevated with respect to normal brain. ROI values of ADC and T2 delivered statistically significant (P < 0.01) differentiation between tumor and edema. Multidimensional parameter combinations improved differentiation between different tissues. However, the three tumor types could not be differentiated. All parameter maps allowed the identification of the whole tumoredema area. On T2 images, edema could be identified best, whereas the tumor itself was hardly visualized. In many cases, tumor presentation using T1 maps corresponded best with histology, nevertheless suffering from a poor tumoredema differentiation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.1910340608

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

Metadata

Authors
Eis, M., Els, T., & Hoehn‐Berlage, M.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
1995-12
Volume
34
Issue
6
Pages
835-844
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2008834642
Cited by
122
References
4
FWCI
3.29
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.