CoChat

Quantitative magnetic resonance imaging of perfusion using magnetic labeling of water proton spins within the detection slice

Schwarzbauer, Christian, Morrissey, Sean P., Haase, Axel · 1996 · Magnetic Resonance in Medicine
Cited by 106

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

A technique for noninvasive quantitative magnetic resonance imaging of perfusion is presented. It relies on using endogenous water as a freely diffusible tracer. Tissue water proton spins are magnetically labeled by slice‐selective inversion, and longitudinal relaxation within the slice is detected using a fast gradient echo magnetic resonance imaging technique. Due to blood flow, nonexcited spins are washed into the slice resulting in an acceleration of the longitudinal relaxation process. Incorporating this phenomenon into the Bloch equation yields an expression that allows quantification of perfusion on the basis of a slice‐selective and a nonselective inversion recovery experiment. Based on this technique, quantitative parameter maps of the regional cerebral blood flow (rCBF) were obtained from eight rats. Evaluation of regions of interest within the cerebral hemispheres yielded an average rCBF value of 104 ± 21 ml/min/100 g, which increased to 219 ± 30 ml/min/100 g during hypercapnia. The measured rCBF values are in good agreement with previously reported literature values.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.1910350413

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 106

Metadata

Authors
Schwarzbauer, C., Morrissey, S. P., & Haase, A.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
1996-04
Volume
35
Issue
4
Pages
540-546
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2040954195
Cited by
106
References
2
FWCI
12.39
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.