Multislice interleaved excitation cycles (MUSIC): An efficient gradient‐echo technique for functional MRI
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
A method providing improved slice efficiency for gradient‐echo imaging requiring long echo times, such as in functional neuromagnetic resonance imaging, is presented. To enhance the volume coverage while maintaining the short imaging time of a conventional single‐slice gradient‐echo technique, an interleaved muttislice excitation is performed during the echo time. This technique allows detection of susceptibility changes, e.g., the acquisition of stimulated human cortical activation maps, on clinical MR instruments at multiple planes within total imaging times of a few seconds. The efficiency of the technique is demonstrated in the detection of temporary changes in T 2* in functional MRI experiments of the human visual cortex at magnetic field strengths of 2 Tesla and 3 Tesla. Fourteen 128 × 128 slices can be acquired in 13 s to cover a large volume‐of‐interest in the same time that would be required for single‐slice acquisition using the conventional technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fox, P. T., & Raichle, M. E. (1986) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.83.4.1140 · Cited by 2,056
Time course EPI of human brain function during task activation
Bandettini, P. A., Wong, E. C., Hinks, R. S., Tikofsky, R. S., & Hyde, J. S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250220 · Cited by 1,935
Thulborn, K. R., Waterton, J. C., Matthews, P. M., & Radda, G. K. (1982) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(82)90333-6 · Cited by 1,134
Cited by
Simultaneous multislice (SMS) imaging techniques
Barth, M., Breuer, F., Koopmans, P. J., Norris, D. G., & Poser, B. A. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25897 · Cited by 534
Evaluation of slice accelerations using multiband echo planar imaging at 3T
Xu, J., Moeller, S., Auerbach, E. J., Strupp, J., Smith, S. M., Feinberg, D. A., Yacoub, E., & Uğurbil, K. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.07.055 · Cited by 514
Functional MRI-BOLD of Visually Triggered Headache in Patients With Migraine
Cao, Y., Welch, K. M. A., Aurora, S., & Vikingstad, E. M. (1999) · Archives of Neurology · doi:10.1001/archneur.56.5.548 · Cited by 340
Cortical Language Activation in Stroke Patients Recovering From Aphasia With Functional MRI
Cao, Y., Vikingstad, E. M., George, K. P., Johnson, A. F., & Welch, K. M. A. (1999) · Stroke · doi:10.1161/01.str.30.11.2331 · Cited by 299
Todd, N., Moeller, S., Auerbach, E. J., Yacoub, E., Flandin, G., & Weiskopf, N. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2015.08.056 · Cited by 173
“Before the advent of multiband imaging, several approaches existed for accelerating 2D acquisitions in the slice direction (Bishop and Plewes, 1991; Crooks et al., 1982; Feinberg et al., 2002; Loenneker et al., 1996) but none became widely adopted.”
Background
Metadata
- Authors
- Loenneker, T., Hennel, F., & Hennig, J.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1996-06
- Volume
- 35
- Issue
- 6
- Pages
- 870-874
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2047058094
- Cited by
- 39
- References
- 3
- FWCI
- 4.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.