CoChat

An in vitro evaluation of the effects of local magnetic‐susceptibility‐induced gradients on anisotropic water diffusion in nerve

Beaulieu, Christian, Allen, Peter S. · 1996 · Magnetic Resonance in Medicine
Cited by 53

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

It has been suggested that the anistropy of the water‐diffusion coefficient measured in nerve and in white matter could arise from locally anisotropic background gradients induced by the static field, Bo. By utilizing 1) pulse sequences, which minimize the effects of background gradients, and 2) changes in sample orientation, which would maximize the change in the magnitude of these gradients if present, it is shown that in four excised nerves the background gradients do not play a measurable role in the anisotropy of the water‐diffusion coefficient at a field strength of 2.35 T. The excised nerves evaluated were the olfactory, trigeminal, and optic nerves of the garfish and the sciatic nerve of the frog.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.1910360108

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

Metadata

Authors
Beaulieu, C., & Allen, P. S.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
1996-07
Volume
36
Issue
1
Pages
39-44
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2029991708
Cited by
53
References
4
FWCI
2.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.