STAR‐HASTE: Perfusion imaging without magnetic susceptibility artifact
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A novel magnetic resonance imaging technique (STAR‐HASTE) based on pulsed arterial spin labeling using a single shot acquisition method is described for perfusion imaging. The method is similar to EPISTAR in using STAR (Signal Targeting with Alternating Radiofrequency) technique for pulsed radiofrequency labeling of inflowing blood, but uses a half‐Fourier single shot turbo spin‐echo (HASTE) sequence for data acquisition instead of echo‐planar imaging (EPI). Our preliminary studies show that STAR‐HASTE permits perfusion imaging to be performed without many of the artifacts encountered with other imaging methods based on EPI acquisition. The novel method not only provides similar perfusion information to that obtained by EPISTAR, as demonstrated in the functional brain imaging study, but also eliminates magnetic susceptibility artifacts and image distortion commonly observed in EPI images. Furthermore, this technique can be readily implemented in MR systems without EPI capability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Time course EPI of human brain function during task activation
Bandettini, P. A., Wong, E. C., Hinks, R. S., Tikofsky, R. S., & Hyde, J. S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250220 · Cited by 1,935
Cited by
Measuring Cerebral Blood Flow Using Magnetic Resonance Imaging Techniques
Calamante, F., Thomas, D. L., Pell, G. S., Wiersma, J., & Turner, R. (1999) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199907000-00001 · Cited by 638
Methodology of brain perfusion imaging
Barbier, E. L., Lamalle, L., & Décorps, M. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1073 · Cited by 404
Comparison of quantitative perfusion imaging using arterial spin labeling at 1.5 and 4.0 Tesla
Wang, J., Alsop, D. C., Li, L., Listerud, J., Gonzalez‐At, J. B., Schnall, M. D., & Detre, J. A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10211 · Cited by 369
Non-invasive measurement of perfusion: a critical review of arterial spin labelling techniques
Petersen, E. T., Zimine, I., Ho, Y.-C. L., & Golay, X. (2006) · The British Journal of Radiology · doi:10.1259/bjr/67705974 · Cited by 352
Detre, J. A., & Alsop, D. C. (1999) · European Journal of Radiology · doi:10.1016/s0720-048x(99)00050-9 · Cited by 299
Metadata
- Authors
- Chen, Q., Siewert, B., Bly, B. M., Warach, S., & Edelman, R. R.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1997-09
- Volume
- 38
- Issue
- 3
- Pages
- 404-408
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2117405474
- Cited by
- 50
- References
- 1
- FWCI
- 3.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.