CoChat

STAR‐HASTE: Perfusion imaging without magnetic susceptibility artifact

Chen, Qun, Siewert, Bettina, Bly, Benjamin Martin, Warach, Steven, Edelman, Robert R. · 1997 · Magnetic Resonance in Medicine
Cited by 50

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

A novel magnetic resonance imaging technique (STAR‐HASTE) based on pulsed arterial spin labeling using a single shot acquisition method is described for perfusion imaging. The method is similar to EPISTAR in using STAR (Signal Targeting with Alternating Radiofrequency) technique for pulsed radiofrequency labeling of inflowing blood, but uses a half‐Fourier single shot turbo spin‐echo (HASTE) sequence for data acquisition instead of echo‐planar imaging (EPI). Our preliminary studies show that STAR‐HASTE permits perfusion imaging to be performed without many of the artifacts encountered with other imaging methods based on EPI acquisition. The novel method not only provides similar perfusion information to that obtained by EPISTAR, as demonstrated in the functional brain imaging study, but also eliminates magnetic susceptibility artifacts and image distortion commonly observed in EPI images. Furthermore, this technique can be readily implemented in MR systems without EPI capability.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.1910380308

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 50

Metadata

Authors
Chen, Q., Siewert, B., Bly, B. M., Warach, S., & Edelman, R. R.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
1997-09
Volume
38
Issue
3
Pages
404-408
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2117405474
Cited by
50
References
1
FWCI
3.78
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.