CoChat

Estimating test‐retest reliability in functional MR imaging II: Application to motor and cognitive activation studies

Noll, Douglas C., Genovese, Christopher R., Nystrom, Leigh E., Vazquez, Alberto L., Forman, Steven D., Eddy, William F., Cohen, Jonathan D. · 1997 · Magnetic Resonance in Medicine
Cited by 111

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Functional magnetic resonance imaging (fMRI) using blood oxygenation contrast has rapidly spread into many application areas. In this paper, a new statistical model is used to evaluate the reliability of fMRI activation in a finger opposition motor paradigm for both within‐session and between‐session data and in a working memory paradigm for between‐session data. A slice prescription procedure for between‐session reproducibility is introduced. Estimates are made for the probabilities of correctly and falsely classifying voxels as active or inactive and receiver operator characteristic curves are generated. In the motor paradigm, estimated between‐session reliability was found to be somewhat reduced relative to within‐session reliability; however, this includes additional sources of variation and may not reflect intrinsically lower reliability. After matching false‐positive classification probabilities, between‐session reliability was found to be nearly identical for both motor and cognitive activation paradigms.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.1910380320

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 111

Metadata

Authors
Noll, D. C., Genovese, C. R., Nystrom, L. E., Vazquez, A. L., Forman, S. D., Eddy, W. F., & Cohen, J. D.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
1997-09
Volume
38
Issue
3
Pages
508-517
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2057314949
Cited by
111
References
6
FWCI
5.14
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Estimating test‐retest reliability in functional MR imaging II: Application to motor and cognitive activation studies. https://app.cochat.ai/papers/10.1002/mrm.1910380320
The paper
Noll, D. C., Genovese, C. R., Nystrom, L. E., Vazquez, A. L., Forman, S. D., Eddy, W. F., & Cohen, J. D. (1997). Estimating test‐retest reliability in functional MR imaging II: Application to motor and cognitive activation studies. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910380320

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.