Functional MRI using steady‐state arterial water labeling
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Flow‐sensitive functional MRI (fMRI) was performed using steady‐state arterial water labeling (SS‐AWL). Arterial water labeling was accomplished by flow induced adiabatic fast passage. The signal intensity of the visual cortex in arterial water labeled images decreased by ˜1.4% during visual stimulation of the brain. Acquisition of arterial water unlabeled and labeled images allows measurement of relative cerebral blood flow increase during brain activation. During visual stimulation, cerebral blood flow in the visual cortex increased by 17 to 35% as measured by SS‐AWL. Quantitation of brain activation in terms of a physiological parameter using SS‐AWL will facilitate comparative fMRI studies under different conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fox, P. T., & Raichle, M. E. (1986) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.83.4.1140 · Cited by 2,056
Nonoxidative Glucose Consumption During Focal Physiologic Neural Activity
Fox, P. T., Raichle, M. E., Mintun, M. A., & Dence, C. (1988) · Science · doi:10.1126/science.3260686 · Cited by 1,796
Cited by
Dai, W., Lopez, O. L., Carmichael, O. T., Becker, J. T., Kuller, L. H., & Gach, H. M. (2009) · Radiology · doi:10.1148/radiol.2503080751 · Cited by 398
Detre, J. A., & Alsop, D. C. (1999) · European Journal of Radiology · doi:10.1016/s0720-048x(99)00050-9 · Cited by 299
Wang, J., Zhang, Y., Wolf, R. L., Roc, A. C., Alsop, D. C., & Detre, J. A. (2005) · Radiology · doi:10.1148/radiol.2351031663 · Cited by 271
Perfusion Imaging Using Arterial Spin Labeling
Golay, X., Hendrikse, J., & Lim, T. C. C. (2004) · Topics in Magnetic Resonance Imaging · doi:10.1097/00002142-200402000-00003 · Cited by 256
Pfefferbaum, A., Chanraud, S., Pitel, A.-L., Muller-Oehring, E., Shankaranarayanan, A., Alsop, D. C., Rohlfing, T., & Sullivan, E. V. (2011) · Cerebral Cortex · doi:10.1093/cercor/bhq090 · Cited by 104
“Initial ASL activation studies used tasks with low demands, such as passive visual stimulation (Talagala and Noll 1998; Aguirre et al. 2002) and memory-guided sequential finger movement task (Garraux et al. 2005) but were successful in causing increases in several task-relevant areas of perfusion…”
Method
Metadata
- Authors
- Talagala, S. L., & Noll, D. C.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1998-02
- Volume
- 39
- Issue
- 2
- Pages
- 179-183
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2065876528
- Cited by
- 42
- References
- 2
- FWCI
- 4.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Functional MRI using steady‐state arterial water labeling. https://app.cochat.ai/papers/10.1002/mrm.1910390203
- The paper
- Talagala, S. L., & Noll, D. C. (1998). Functional MRI using steady‐state arterial water labeling. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910390203
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.