The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Concomitant gradient terms in phase contrast MR: Analysis and correction
Abstract
Whenever a linear gradient is activated, concomitant magnetic fields with non‐linear spatial dependence result. This is a consequence of Maxwell's equations, i.e., within the imaging volume the magnetic field must have zero divergence, and has negligible curl. The concomitant, or Maxwell field has been described in the MRI literature for over 10 years. In this paper, we theoretically and experimentally show the existence of two additional lowest‐order terms in the concomitant field, which we call cross‐terms. The concomitant gradient cross‐terms only arise when the longitudinal gradient G z is simultaneously active with a transverse gradient (G x or G y). The effect of all of the concomitant gradient terms on phase contrast imaging is examined in detail. Several methods for reducing or eliminating phase errors arising from the concomitant magnetic field are described. The feasibility of a joint pulse sequence‐reconstruction method, which requires no increase in minimum TE, is demonstrated. Since the lowest‐order terms of the concomitant field are proportional to G2/B0, the importance of concomitant gradient terms is expected to increase given the current interest in systems with stronger gradients and/or weaker main magnetic fields.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Principles of Nuclear Magnetism
Abragam, A., & Hebel, L. C. (1961) · American Journal of Physics · doi:10.1119/1.1937646 · Cited by 15,792
Classical Electrodynamics: From Image Charges to the Photon Mass and Magnetic Monopoles
Lacava, F. (2022) · Undergraduate Lecture Notes in Physics · doi:10.1007/978-3-031-05099-2 · Cited by 895
A flow velocity zeugmatographic interlace for NMR imaging in humans
Moran, P. R. (1982) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(82)90170-9 · Cited by 745
Blood Flow Imaging by Cine Magnetic Resonance
Nayler, G. L., Firmin, D. N., & Longmore, D. B. (1986) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198609000-00001 · Cited by 634
Measurement of Flow with NMR Imaging Using a Gradient Pulse and Phase Difference Technique
Bryant, D. J., Payne, J. A., Firmin, D. N., & Longmore, D. B. (1984) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198408000-00002 · Cited by 545
Three‐dimensional phase contrast angiography
Dumoulin, C. L., Souza, S. P., Walker, M. F., & Wagle, W. (1989) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910090117 · Cited by 432
Reconstructions of phase contrast, phased array multicoil data
Bernstein, M. A., Grgic, M., Brosnan, T. J., & Pelc, N. J. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320308 · Cited by 162
Self-citationNMR blood flow imaging using multiecho, phase contrast sequences
O'Donnell, M. (1985) · Medical Physics · doi:10.1118/1.595736 · Cited by 158
Concomitant magnetic field gradients and their effects on imaging at low magnetic field strengths
Norris, D. G., & Hutchison, J. M. S. (1990) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(90)90209-k · Cited by 127
Image restoration from non-uniform magnetic field influence for direct Fourier NMR imaging
Sekihara, K., Kuroda, M., & Kohno, H. (1984) · Physics in Medicine and Biology · doi:10.1088/0031-9155/29/1/002 · Cited by 76
Cited by
Design and validation of Segment - freely available software for cardiovascular image analysis
Heiberg, E., Sjögren, J., Ugander, M., Carlsson, M., Engblom, H., & Arheden, H. (2010) · BMC Medical Imaging · doi:10.1186/1471-2342-10-1 · Cited by 929
4D flow cardiovascular magnetic resonance consensus statement
Dyverfeldt, P., Bissell, M., Barker, A. J., Bolger, A. F., Carlhäll, C.-J., Ebbers, T., Francios, C. J., Frydrychowicz, A., Geiger, J., Giese, D., et al. (2015) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-015-0174-5 · Cited by 877
Markl, M., Frydrychowicz, A., Kozerke, S., Hope, M., & Wieben, O. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23632 · Cited by 788
DENSE: Displacement Encoding with Stimulated Echoes in Cardiac Functional MRI
Aletras, A. H., Ding, S., Balaban, R. S., & Wen, H. (1999) · Journal of Magnetic Resonance · doi:10.1006/jmre.1998.1676 · Cited by 526
Quantitative susceptibility mapping: current status and future directions
Haacke, E. M., Liu, S., Buch, S., Zheng, W., Wu, D., & Ye, Y. (2015) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2014.09.004 · Cited by 511
Markl, M., Kilner, P. J., & Ebbers, T. (2011) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-13-7 · Cited by 463
Bicuspid Aortic Valve: Four-dimensional MR Evaluation of Ascending Aortic Systolic Flow Patterns
Hope, M. D., Hope, T. A., Meadows, A. K., Ordovas, K. G., Urbania, T. H., Alley, M. T., & Higgins, C. B. (2010) · Radiology · doi:10.1148/radiol.09091437 · Cited by 417
Fast, iterative image reconstruction for MRI in the presence of field inhomogeneities
Sutton, B. P., Noll, D. C., & Fessler, J. A. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.808360 · Cited by 397
Applications of phase-contrast flow and velocity imaging in cardiovascular MRI
Gatehouse, P. D., Keegan, J., Crowe, L. A., Masood, S., Mohiaddin, R. H., Kreitner, K.-F., & Firmin, D. N. (2005) · European Radiology · doi:10.1007/s00330-005-2829-3 · Cited by 331
Multidimensional X-Space Magnetic Particle Imaging
Goodwill, P. W., & Conolly, S. M. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2125982 · Cited by 319
Stanković, Z. B., Allen, B. D., García, J., Jarvis, K., & Markl, M. (2014) · PubMed · doi:10.3978/j.issn.2223-3652.2014.01.02 · Cited by 281
Cardiovascular magnetic resonance phase contrast imaging
Nayak, K. S., Nielsen, J.-F., Bernstein, M. A., Markl, M., D. Gatehouse, P., M. Botnar, R., Saloner, D., Lorenz, C., Wen, H., S. Hu, B., et al. (2015) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-015-0172-7 · Cited by 264
Self-citationGatehouse, P. D., Rolf, M. P., Graves, M. J., Hofman, M. B., Totman, J., Werner, B., Quest, R. A., Liu, Y., von Spiczak, J., Dieringer, M., et al. (2010) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-12-5 · Cited by 234
Engineering clinical translation of OGSE diffusion MRI
Zhu, A., Michael, E. S., Li, H., Sprenger, T., Hua, Y., Lee, S., Yeo, D. T. B., McNab, J. A., Hennel, F., Fieremans, E., et al. (2025) · Magnetic Resonance in Medicine · doi:10.1002/mrm.30510 · Cited by 13
Metadata
- Authors
- Bernstein, M. A., Zhou, X. J., Polzin, J. A., King, K. F., Ganin, A., Pelc, N. J., & Glover, G. H.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1998-02
- Volume
- 39
- Issue
- 2
- Pages
- 300-308
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1965852118
- Cited by
- 547
- References
- 11
- FWCI
- 8.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.