Multislice imaging of quantitative cerebral perfusion with pulsed arterial spin labeling
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A method is presented for multislice measurements of quantitative cerebral perfusion based on magnetic labeling of arterial spins. The method combines a pulsed arterial inversion, known as the FAIR (Flow‐sensitive Alternating Inversion Recovery) experiment, with a fast spiral scan image acquisition. The short duration (22 ms) of the spiral data collection allows simultaneous measurement of up to 10 slices per labeling period, thus dramatically increasing efficiency compared to current single slice acquisition protocols. Investigation of labeling efficiency, suppression of unwanted signals from stationary as well as intraarterial spins, and the FAIR signal change as a function of inversion delay are presented. The assessment of quantitative cerebral blood flow (CBF) with the new technique is demonstrated and shown to require measurement of arterial transit time as well as suppression of intraarterial spin signals. CBF values measured on normal volunteers are consistent with results obtained from H 2 O 15 positron emission tomography (PET) studies and other radioactive tracer approaches. In addition, the new method allows detection of activation‐related perfusion changes in a finger‐tapping experiment, with locations of activation corresponding well to those observed with blood oxygen level dependent (BOLD) fMRI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212
Functional mapping of the human visual cortex by magnetic resonance imaging
Belliveau, J. W., Kennedy, D. N., McKinstry, R. C., Buchbinder, B. R., Weisskoff, R. M., Cohen, M. S., Vevea, J. M., Brady, T. J., & Rosen, B. R. (1991) · Science · doi:10.1126/science.1948051 · Cited by 1,883
Cited by
Measuring Cerebral Blood Flow Using Magnetic Resonance Imaging Techniques
Calamante, F., Thomas, D. L., Pell, G. S., Wiersma, J., & Turner, R. (1999) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199907000-00001 · Cited by 638
Methodology of brain perfusion imaging
Barbier, E. L., Lamalle, L., & Décorps, M. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1073 · Cited by 404
Comparison of quantitative perfusion imaging using arterial spin labeling at 1.5 and 4.0 Tesla
Wang, J., Alsop, D. C., Li, L., Listerud, J., Gonzalez‐At, J. B., Schnall, M. D., & Detre, J. A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10211 · Cited by 369
Non-invasive measurement of perfusion: a critical review of arterial spin labelling techniques
Petersen, E. T., Zimine, I., Ho, Y.-C. L., & Golay, X. (2006) · The British Journal of Radiology · doi:10.1259/bjr/67705974 · Cited by 352
Using network science to evaluate exercise-associated brain changes in older adults.
Burdette (2010) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2010.00023 · Cited by 320
“the hIPPocaMPus and Its role In exercIse Several studies have shown alterations in the hippocampus following exercise. For example, Pereira et al. (2007) showed that CBV is elevated in exercised adults using a bolus-gadolinium perfusion MRI technique, and furthermore, that these increases in CBV are correlated with ae…”
Influential
Metadata
- Authors
- Yang, Y., Frank, J. A., Hou, L., Ye, F. Q., McLaughlin, A. C., & Duyn, J. H.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1998-05
- Volume
- 39
- Issue
- 5
- Pages
- 825-832
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1992072691
- Cited by
- 155
- References
- 2
- FWCI
- 13.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.