The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
In vivo measurement of T*2 and field inhomogeneity maps in the human heart at 1.5 T
Open accessAbstract
Cardiac echo‐planar imaging suffers invariably from regions of severe distortion and T*2 decay in the myocardium. The purpose of this work was to perform local measurements of T*2 and field inhomogeneities in the myocardium and to identify the sources of focal signal loss and distortion. Field inhomogeneity maps and T*2 were measured in five normal volunteers in short‐axis slices spanning from base to apex. It was found that T*2 ranged from 26 ms (SD = 7 ms, n = 5) to 41 ms (SD = 11 ms, n = 5) over most of the heart, and peak‐to‐peak field inhomogeneity differences were 71 Hz (SD = 14 Hz, n = 5). In all hearts, regions of severe signal loss were consistently adjacent to the posterior vein of the left ventricle; T*2 in these regions was 12 ms (SD = 2 ms, n = 5), and the difference in resonance frequency with the surrounding myocardium was 70‐100 Hz. These effects may be caused by increased magnetic susceptibility from deoxygenated blood in these veins.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain magnetic resonance imaging with contrast dependent on blood oxygenation.
Ogawa, S., Lee, T. M., Kay, A. R., & Tank, D. W. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.24.9868 · Cited by 6,483
Thulborn, K. R., Waterton, J. C., Matthews, P. M., & Radda, G. K. (1982) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(82)90333-6 · Cited by 1,134
Cited by
Multicoil Dixon chemical species separation with an iterative least‐squares estimation method
Reeder, S. B., Wen, Z., Yu, H., Pineda, A. R., Gold, G. E., Markl, M., & Pelc, N. J. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10675 · Cited by 508
Self-citationSaturation recovery single‐shot acquisition (SASHA) for myocardial T1 mapping
Chow, K., Flewitt, J. A., Green, J. D., Pagano, J. J., Friedrich, M. G., & Thompson, R. B. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24878 · Cited by 396
Metadata
- Authors
- Reeder, S. B., Faranesh, A. Z., Boxerman, J. L., & McVeigh, E. R.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1998-06
- Volume
- 39
- Issue
- 6
- Pages
- 988-998
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2038962358
- Cited by
- 189
- References
- 2
- FWCI
- 5.82
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In vivo measurement of T*2 and field inhomogeneity maps in the human heart at 1.5 T. https://app.cochat.ai/papers/10.1002/mrm.1910390617
- The paper
- Reeder, S. B., Faranesh, A. Z., Boxerman, J. L., & McVeigh, E. R. (1998). In vivo measurement of T*2 and field inhomogeneity maps in the human heart at 1.5 T. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910390617
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.