The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
SAR and B1 field distributions in a heterogeneous human head model within a birdcage coil
Abstract
Calculations of radiofrequency magnetic (B 1) field and specific energy absorption rate (SAR) distributions in a sphere of tissue and a multi‐tissue human head model in a 12‐element birdcage coil are presented. The coil model is driven in linear and quadrature modes at 63, 175, 200, and 300 MHz. Plots of B, field magnitude and SAR distributions, average SAR, maximum local SAR, and measures of B 1 field homogeneity and signal‐to‐noise ratio are given. SAR levels for arbitrary pulse sequences can be estimated from the calculated data. Maximum local SAR levels are lower at lower frequencies, in quadrature rather than in linear coils, and in linear fields oriented posterior‐to‐anterior rather than left‐to‐right in the head. It should be possible to perform many experiments in the head at frequencies up to 300 MHz without exceeding standard limits for local or average SAR levels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Yee, K. (1966) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.1966.1138693 · Cited by 15,008
Compilation of the Dielectric Properties of Body Tissues at RF and Microwave Frequencies.
Gabriel, C. (1996) · doi:10.21236/ada303903 · Cited by 2,097
Bottomley, P. A., & Andrew, E. R. (1978) · Physics in Medicine & Biology · doi:10.1088/0031-9155/23/4/006 · Cited by 407
Comparison of linear and circular polarization for magnetic resonance imaging
Glover, G. H., Hayes, C. E., Pelc, N. J., Edelstein, W. A., Mueller, O. M., Hart, H. R., Hardy, C. J., O'Donnell, M., & Barber, W. D. (1985) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(85)90349-x · Cited by 265
Estimating radiofrequency power deposition in body NMR imaging
Bottomley, P. A., Redington, R. W., Edelstein, W. A., & Schenck, J. F. (1985) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910020404 · Cited by 171
Hornak, J. P., Szumowski, J., & Bryant, R. G. (1988) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910060204 · Cited by 104
On the SAR and field inhomogeneity of birdcage coils loaded with the human head
Jin, J., & Chen, J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380615 · Cited by 92
Šimunić, D., Wach, P., Renhart, W., & Stollberger, R. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.477704 · Cited by 84
Homogeneous Tissue Model Estimates of RF Power Deposition in Human NMR Studies
Bottomley, P. A., & Roemer, P. (1992) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1992.tb49604.x · Cited by 42
Magnetic resonance imaging: Calculation of rates of energy absorption by a human‐torso model
Grandolfo, M., Vecchia, P., & Gandhi, O. P. (1990) · Bioelectromagnetics · doi:10.1002/bem.2250110203 · Cited by 36
Cited by
7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images
Vaughan, J. T., Garwood, M., Collins, C. M., Liu, W., DelaBarre, L., Adriany, G., Andersen, P., Merkle, H., Goebel, R., Smith, M. B., et al. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1156 · Cited by 890
Self-citationChallenges for Molecular Magnetic Resonance Imaging
Terreno, E., Castelli, D. D., Viale, A., & Aime, S. (2010) · Chemical Reviews · doi:10.1021/cr100025t · Cited by 855
B1 destructive interferences and spatial phase patterns at 7 T with a head transceiver array coil
Van de Moortele, P., Akgun, C., Adriany, G., Moeller, S., Ritter, J., Collins, C. M., Smith, M. B., Vaughan, J. T., & Uğurbil, K. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20708 · Cited by 468
Self-citationProteoglycan‐induced changes in T1ρ‐relaxation of articular cartilage at 4T
Akella, S. V. S., Reddy Regatte, R., Gougoutas, A. J., Borthakur, A., Shapiro, E. M., Kneeland, J. B., Leigh, J. S., & Reddy, R. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1208 · Cited by 381
9.4T human MRI: Preliminary results
Vaughan, T., DelaBarre, L., Snyder, C., Tian, J., Akgun, C., Shrivastava, D., Liu, W., Olson, C., Adriany, G., Strupp, J., et al. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21073 · Cited by 317
Metadata
- Authors
- Collins, C. M., Li, S., & Smith, M. B.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1998-12
- Volume
- 40
- Issue
- 6
- Pages
- 847-856
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2008958501
- Cited by
- 272
- References
- 10
- FWCI
- 7.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.