The DOI matches its Crossref record.
In vivo monitoring of tissue pharmacokinetics of liposome/drug using MRI: Illustration of targeted delivery
Abstract
The purpose of this study was to determine if MnSO 4/doxorubicin (DOX) loaded liposomes could be used for in vivo monitoring of liposome concentration distribution and drug release using MRI. In vitro results show that T1 shortening correlates with MnSO 4 concentration. Using a temperature‐sensitive liposome formulation, it was found that MnSO 4 release significantly shortened T1. This feature, therefore, suggests that content release can also be measured with these MnSO 4‐loaded liposomes. The feasibility of monitoring this drug delivery and release‐imaging agent was shown in a murine tumor model. Upon tumor heating, nonthermally sensitive liposomes selectively but heterogeneously accumulated in the tumor region. The thermally sensitive liposomes showed a clear pattern of accumulation at the periphery of the tumor, concordant with the release temperature of this formulation (39–40°C). This liposome contrast agent has potential for use with hyperthermia by providing individualized monitoring of tissue drug concentration distribution during or after treatment. This would allow for: 1) modification of treatment variables to improve the uniformity of drug delivery, and 2) provide a means to select patients most likely to benefit from this liposomal drug treatment. Additionally, the drug‐loading method used for this liposome is applicable to a wide range of drugs, thereby broadening its applicability. The method is also applicable to other liposomal formulations with triggered release mechanisms. Magn Reson Med 51:1153–1162, 2004. © 2004 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Recent advances with liposomes as pharmaceutical carriers
Torchilin, V. P. (2005) · Nature Reviews Drug Discovery · doi:10.1038/nrd1632 · Cited by 5,282
Transport of drugs from blood vessels to tumour tissue
Dewhirst, M. W., & Secomb, T. W. (2017) · Nature Reviews Cancer · doi:10.1038/nrc.2017.93 · Cited by 749
Self-citationVillaraza, A. J. L., Bumb, A., & Brechbiel, M. W. (2010) · Chemical Reviews · doi:10.1021/cr900232t · Cited by 632
Determination of Doxorubicin Levels in Whole Tumor and Tumor Nuclei in Murine Breast Cancer Tumors
Laginha, K. M., Verwoert, S., Charrois, G. J. R., & Allen, T. M. (2005) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-05-0343 · Cited by 441
Nanotheranostics and image-guided drug delivery: current concepts and future directions
Lammers, T., Kiessling, F., Hennink, W. E., & Storm, G. (2010) · Molecular Pharmaceutics · doi:10.1021/mp100228v · Cited by 397
Metadata
- Authors
- Viglianti, B. L., Abraham, S. A., Michelich, C. R., Yarmolenko, P. S., MacFall, J. R., Bally, M. B., & Dewhirst, M. W.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2004-05-24
- Volume
- 51
- Issue
- 6
- Pages
- 1153-1162
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2104631267
- Cited by
- 192
- References
- 0
- FWCI
- 5.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In vivo monitoring of tissue pharmacokinetics of liposome/drug using MRI: Illustration of targeted delivery. https://app.cochat.ai/papers/10.1002/mrm.20074
- The paper
- Viglianti, B. L., Abraham, S. A., Michelich, C. R., Yarmolenko, P. S., MacFall, J. R., Bally, M. B., & Dewhirst, M. W. (2004). In vivo monitoring of tissue pharmacokinetics of liposome/drug using MRI: Illustration of targeted delivery. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.20074
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.