CoChat

Variable‐rate selective excitation for rapid MRI sequences

Open access
Hargreaves, Brian A., Cunningham, Charles H., Nishimura, Dwight G., Conolly, Steven M. · 2004 · Magnetic Resonance in Medicine
Cited by 189

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Abstract

Balanced steady‐state free precession (SSFP) imaging sequences require short repetition times (TRs) to avoid off‐resonance artifacts. The use of slab‐selective excitations is common, as this can improve imaging speed by limiting the field of view (FOV). However, the necessarily short‐duration excitations have poor slab profiles. This results in unusable slices at the slab edge due to significant flip‐angle variations or aliasing in the slab direction. Variable‐rate selective excitation (VERSE) is a technique by which a time‐varying gradient waveform is combined with a modified RF waveform to provide the same excitation profile with different RF power and duration characteristics. With the use of VERSE, it is possible to design short‐duration pulses with dramatically improved slab profiles. These pulses achieve high flip angles with only minor off‐resonance sensitivity, while meeting SAR limits at 1.5 T. The improved slab profiles will enable more rapid 3D imaging of limited volumes, with more consistent image contrast across the excited slab. Magn Reson Med 52:590–597, 2004. © 2004 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.20168

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 14 references

Cited by

See all 189

Metadata

Authors
Hargreaves, B. A., Cunningham, C. H., Nishimura, D. G., & Conolly, S. M.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2004-08-23
Volume
52
Issue
3
Pages
590-597
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2078208347
Cited by
189
References
14
FWCI
6.42
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Variable‐rate selective excitation for rapid MRI sequences. https://app.cochat.ai/papers/10.1002/mrm.20168
The paper
Hargreaves, B. A., Cunningham, C. H., Nishimura, D. G., & Conolly, S. M. (2004). Variable‐rate selective excitation for rapid MRI sequences. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.20168

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.