The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Electrodynamics and ultimate SNR in parallel MR imaging
Open accessAbstract
The purpose of this article is to elucidate inherent limitations to the performance of parallel MRI. The study focuses on the ultimate signal‐to‐noise ratio (SNR), which refers to the maximum SNR permitted by the electrodynamics of the signal detection process. Using a spherical model object, it is shown that the behavior of the ultimate SNR imposes distinct limits on the acceleration rate in parallel imaging. For low and moderate acceleration, the ultimate SNR performance is nearly optimal, with geometry factors close to 1. However, for high reduction factors beyond a critical value, the ultimate performance deteriorates rapidly, corresponding to exponential growth of the geometry factor. The transition from optimal to deteriorating performance depends on the electrodynamic characteristics of the detected RF fields. In the near‐field regime, i.e., for low B0 and small object size, the critical reduction factor is constant and approximately equal to four for 1D acceleration in the sphere. In the far‐field wave regime the critical reduction factor is larger and increases both with B0 and object size. Therefore, it is concluded that parallel techniques hold particular promise for human MR imaging at very high field. Magn Reson Med 52:376–390, 2004. © 2004 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2020) · Electromagnetic Processes · doi:10.2307/j.ctv131bv37.5 · Cited by 21,966
Introduction to Fourier optics
Goodman, J. W. (1968) · Cited by 10,608
Greiner, W. (1998) · Theoretical Physics · doi:10.1007/978-1-4612-0587-6 · Cited by 6,657
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Self-citationGeneralized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellus, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,303
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/003 · Cited by 4,175
Thermal Agitation of Electric Charge in Conductors
Nyquist, H. (1928) · Physical Review · doi:10.1103/physrev.32.110 · Cited by 3,115
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142
Thermal Agitation of Electricity in Conductors
Johnson, J. B. (1928) · Physical Review · doi:10.1103/physrev.32.97 · Cited by 1,811
Mathematical Methods for Physicists: A Concise Introduction
Chow, T. L. (2000) · Cambridge University Press eBooks · doi:10.1017/cbo9780511755781 · Cited by 1,326
Advances in sensitivity encoding with arbitrary k‐space trajectories
Pruessmann, K. P., Weiger, M., Börnert, P., & Boesiger, P. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1241 · Cited by 1,211
Self-citationThe signal-to-noise ratio of the nuclear magnetic resonance experiment
Hoult, D. I., & Richards, R. E. (1976) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(76)90233-x · Cited by 1,132
The signal-to-noise ratio of the nuclear magnetic resonance experiment
Hoult, D. I., & Richards, R. E. (2011) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2011.09.018 · Cited by 995
The principle of reciprocity in signal strength calculations?A mathematical guide
Hoult, D. I. (2000) · Concepts in Magnetic Resonance · doi:10.1002/1099-0534(2000)12:4<173::aid-cmr1>3.0.co;2-q · Cited by 550
AUTO-SMASH: A self-calibrating technique for SMASH imaging
Jakob, P. M., Grisowld, M. A., Edelman, R. R., & Sodickson, D. K. (1998) · Magma: Magnetic Resonance Materials in Physics, Biology, and Medicine · doi:10.1007/bf02592256 · Cited by 278
Sensitivity profiles from an array of coils for encoding and reconstruction in parallel (SPACE RIP)
Kyriakos, W. E., Panych, L. P., Kacher, D. F., Westin, C.-F., Bao, S. M., Mulkern, R. V., & Jolesz, F. A. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200008)44:2<301::aid-mrm18>3.0.co;2-d · Cited by 253
Ultimate intrinsic signal‐to‐noise ratio for parallel MRI: Electromagnetic field considerations
Ohliger, M. A., Grant, A. K., & Sodickson, D. K. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10597 · Cited by 238
Weiger, M., Pruessmann, K. P., & Boesiger, P. (2002) · Magnetic Resonance Materials in Physics, Biology and Medicine · doi:10.1007/bf02668182 · Cited by 226
Self-citationDesign of a SENSE‐optimized high‐sensitivity MRI receive coil for brain imaging
de Zwart, J. A., Ledden, P. J., Kellman, P., van Gelderen, P., & Duyn, J. H. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10169 · Cited by 192
Specific coil design for SENSE: A six-element cardiac array
Weiger, M., Pruessmann, K. P., Leussler, C. G., R�schmann, P., & Boesiger, P. (2001) · Magnetic Resonance in Medicine · Cited by 183
Self-citationMultipole expansions and plane wave representations of the electromagnetic field
Devaney, A. J., & Wolf, E. (1974) · Journal of Mathematical Physics · doi:10.1063/1.1666629 · Cited by 181
Cited by
Moeller, S., Yacoub, E., Olman, C. A., Auerbach, E., Strupp, J., Harel, N., & Uğurbil, K. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22361 · Cited by 1,586
Parallel magnetic resonance imaging
Larkman, D. J., & Nunes, R. G. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/7/r01 · Cited by 327
Reeder, S. B., Wintersperger, B. J., Dietrich, O., Lanz, T., Greiser, A., Reiser, M. F., Glazer, G. M., & Schoenberg, S. O. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20636 · Cited by 302
Array compression for MRI with large coil arrays
Buehrer, M., Pruessmann, K. P., Boesiger, P., & Kozerke, S. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21237 · Cited by 257
Self-citationClinically feasible NODDI characterization of glioma using multiband EPI at 7 T
Wen, Q., Kelley, D. A. C., Banerjee, S., Lupo, J. M., Chang, S. M., Xu, D., Hess, C. P., & Nelson, S. J. (2015) · NeuroImage: Clinical · doi:10.1016/j.nicl.2015.08.017 · Cited by 88
Metadata
- Authors
- Wiesinger, F., Boesiger, P., & Pruessmann, K. P.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2004-07-23
- Volume
- 52
- Issue
- 2
- Pages
- 376-390
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2088713542
- Cited by
- 282
- References
- 21
- FWCI
- 13.63
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.