Quantifying the intra‐ and extravascular contributions to spin‐echo fMRI at 3 T
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Functional MRI (fMRI) by means of spin‐echo (SE) techniques provides an interesting alternative to gradient‐echo methods because the contrast is based primarily on dynamic averaging associated with the blood oxygenation level‐dependent (BOLD) effect. In this article the contributions from different brain compartments to BOLD signal changes in SE echo planar imaging (EPI) are investigated. To gain a better understanding of the underlying mechanisms that cause the fMRI contrast, two experiments are presented: First, the intravascular contribution is decomposed into two fractions with different regimes of flow by means of diffusion‐weighting gradient schemes which are either flow‐compensated, or will maximally dephase moving spins. Second, contributions from the intra‐ and extravascular space are selectively suppressed by combining flow‐weighting with additional refocusing pulses. The results indicate two qualitatively different components of flowing blood which contribute to the BOLD contrast and a nearly equal share in functional signal from the intra‐ and extravascular compartments at TE ≈ 80 ms and 3 T. Combining these results, there is evidence that at least one‐half of the functional signal originates from the parenchyma in SE fMRI at 3 T. The authors suggest the use of flow‐compensated diffusion weighting for SE fMRI to improve the sensitivity to the parenchyma. Magn Reson Med 52:724–732, 2004. © 2004 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Le Bihan, D., Breton, E., Lallemand, D., Grenier, P., Cabanis, E., & Laval-Jeantet, M. (1986) · Radiology · doi:10.1148/radiology.161.2.3763909 · Cited by 3,912
Magnetic Resonance Imaging: Physical Principles and Sequence Design
Brown, R. W., Cheng, Y. N., Haacke, E. M., Thompson, M. R., & Venkatesan, R. (2014) · doi:10.1002/9781118633953 · Cited by 2,688
Diffusion weighted fMRI at 1.5 T
Song, A. W., Wong, E. C., Tan, S. G., & Hyde, J. S. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350204 · Cited by 208 · cited 1×
“Due to this two-compartment effect, the relative fMRI contrast is reduced by the application of velocitysensitive gradient schemes (2,3) which remove intravascular signal contributions.”
Background
Cited by
Biophysical and Physiological Origins of Blood Oxygenation Level-Dependent fMRI Signals
Kim, S.-G., & Ogawa, S. (2012) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2012.23 · Cited by 547
Uludağ, K., Müller-Bierl, B., & Uğurbil, K. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.05.051 · Cited by 450
“For SE at 3 T, half of the BOLD signal has experimentally been found to arise from IV (Norris et al., 2002) of which 30–40% stems from the microvasculature (Jochimsen et al., 2004); from the model, the IV contribution to the total SE fMRI signal is expected to be slightly higher.”
BackgroundMethodInfluentialSpatio-temporal point-spread function of fMRI signal in human gray matter at 7 Tesla
Shmuel, A., Yacoub, E., Chaimow, D., Logothetis, N. K., & Ugurbil, K. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.12.030 · Cited by 294
“Even at 3 T and irrespective of whether GE or SE acquisition is used, BOLD fMRI signals are dominated by contributions from blood, and hence large veins ( Jochimsen et al., 2004 ).”
BackgroundQuantifying the spatial resolution of the gradient echo and spin echo BOLD response at 3 Tesla
Parkes, L. M., Schwarzbach, J. V., Bouts, A. A., Deckers, R. H. R., Pullens, P., Kerskens, C. M., & Norris, D. G. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20712 · Cited by 187
Self-citationImaging at ultrahigh magnetic fields: History, challenges, and solutions
Uğurbil, K. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.07.007 · Cited by 173
“Consistent with these results, blood contribution to SE fMRI was shown to be a significant contribution at 3 T (∼50% of the functional mapping signals) (Jochimsen et al., 2004), which implies that, combined with the inherently low sensitivity, SE based fMRI at 3 T is relatively useless.”
BackgroundResult
Metadata
- Authors
- Jochimsen, T. H., Norris, D. G., Mildner, T., & Möller, H. E.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2004-09-23
- Volume
- 52
- Issue
- 4
- Pages
- 724-732
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1994431325
- Cited by
- 71
- References
- 3
- FWCI
- 5.08
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.