Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 187

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Quantifying the spatial resolution of the gradient echo and spin echo BOLD response at 3 Tesla

Open access
Parkes, Laura M., Schwarzbach, Jens V., Bouts, Annemieke A., Deckers, Roel h R., Pullens, Pim, Kerskens, Christian M., Norris, David G.·2005·Magnetic Resonance in Medicine

Abstract

The blood oxygen level dependent (BOLD) response, as measured with fMRI, offers good spatial resolution compared to other non‐invasive neuroimaging methods. The use of a spin echo technique rather than the conventional gradient echo technique may further improve the resolution by refocusing static dephasing effects around the larger vessels, so sensitizing the signal to the microvasculature. In this work the width of the point spread function (PSF) of the BOLD response at a field strength of 3 Tesla is compared for these two approaches. A double echo EPI pulse sequence with simultaneous collection of gradient echo and spin echo signal allows a direct comparison of the techniques. Rotating multiple‐wedge stimuli of different spatial frequencies are used to estimate the width of the BOLD response. Waves of activation are created on the surface of the visual cortex, which begin to overlap as the wedge separation decreases. The modulation of the BOLD response decreases with increasing spatial frequency in a manner dependent on its width. The spin echo response shows a 13% reduction in the width of the PSF, but at a cost of at least 3‐fold reduction in contrast to noise ratio. Magn Reson Med, 2005. © 2005 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.20712

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 187

Metadata

Authors
Parkes, L. M., Schwarzbach, J. V., Bouts, A. A., Deckers, R. H. R., Pullens, P., Kerskens, C. M., & Norris, D. G.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2005-11-07
Volume
54
Issue
6
Pages
1465-1472
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W1977819996
Cited by
187
References
2
FWCI
3.33
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quantifying the spatial resolution of the gradient echo and spin echo BOLD response at 3 Tesla. https://app.cochat.ai/papers/10.1002/mrm.20712
The paper
Parkes, L. M., Schwarzbach, J. V., Bouts, A. A., Deckers, R. H. R., Pullens, P., Kerskens, C. M., & Norris, D. G. (2005). Quantifying the spatial resolution of the gradient echo and spin echo BOLD response at 3 Tesla. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.20712

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.