The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Point spread function mapping with parallel imaging techniques and high acceleration factors: Fast, robust, and flexible method for echo‐planar imaging distortion correction
Open accessAbstract
Echo‐planar imaging (EPI) is an ultrafast magnetic resonance (MR) imaging technique prone to geometric distortions. Various correction techniques have been developed to remedy these distortions. Here improvements of the point spread function (PSF) mapping approach are presented, which enable reliable and fully automated distortion correction of echo‐planar images at high field strengths. The novel method is fully compatible with EPI acquisitions using parallel imaging. The applicability of parallel imaging to further accelerate PSF acquisition is shown. The possibility of collecting PSF data sets with total acceleration factors higher than the number of coil elements is demonstrated. Additionally, a new approach to visualize and interpret distortions in the context of various imaging and reconstruction methods based on the PSF is proposed. The reliable performance of the PSF mapping technique is demonstrated on phantom and volunteer scans at field strengths of up to 4 T. Magn Reson Med 52:1156–1166, 2004. © 2004 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellus, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,303
Roemer, P. B., Edelstein, W. A., Hayes, C. E., Souza, S. P., & Mueller, O. M. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160203 · Cited by 2,322
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142
Multi-planar image formation using NMR spin echoes
Mansfield, P. (1977) · Journal of Physics C: Solid State Physics · doi:10.1088/0022-3719/10/3/004 · Cited by 1,813
Correction for geometric distortion in echo planar images from B 0 field variations
Jezzard, P., & Balaban, R. S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340111 · Cited by 1,421
B-spline signal processing. I. Theory
Unser, M., Aldroubi, A., & Eden, M. (1993) · IEEE Transactions on Signal Processing · doi:10.1109/78.193220 · Cited by 940
Interpolation revisited [medical images application]
Thevenaz, P., Blu, T., & Unser, M. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.875199 · Cited by 842
B-spline signal processing. II. Efficiency design and applications
Unser, M., Aldroubi, A., & Eden, M. (1993) · IEEE Transactions on Signal Processing · doi:10.1109/78.193221 · Cited by 641
B-SPLINE SIGNAL PROCESSING: PART I-THEORY
Unser, M. A., Aldroubi, A., & Eden, M. (1993) · Cited by 626
B-SPLINE SIGNAL PROCESSING: PART II-EFFICIENT DESIGN AND APPLICATIONS
Unser, M. A., Aldroubi, A., & Eden, M. (1993) · Cited by 463
Characterization of and correction for eddy current artifacts in echo planar diffusion imaging
Jezzard, P., Barnett, A. S., & Pierpaoli, C. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390518 · Cited by 352
Cusack, R., & Papadakis, N. (2002) · NeuroImage · doi:10.1006/nimg.2002.1092 · Cited by 287
Image distortion correction in EPI: Comparison of field mapping with point spread function mapping
Zeng, H., & Constable, R. T. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10200 · Cited by 274
Heidemann, R. M., Griswold, M. A., Haase, A., & Jakob, P. M. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1141 · Cited by 228
Correction of off resonance‐related distortion in echo‐planar imaging using EPI‐based field maps
Reber, P. J., Wong, E. C., Buxton, R. B., & Frank, L. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390223 · Cited by 223
MOMS: maximal-order interpolation of minimal support
Blu, T., Thcvenaz, P., & Unser, M. (2001) · IEEE Transactions on Image Processing · doi:10.1109/83.931101 · Cited by 205
Self‐calibrating parallel imaging with automatic coil sensitivity extraction
McKenzie, C. A., Yeh, E. N., Ohliger, M. A., Price, M. D., & Sodickson, D. K. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10087 · Cited by 189
Measurement of the point spread function in MRI using constant time imaging
Robson, M. D., Gore, J. C., & Constable, R. T. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380509 · Cited by 161
Concomitant magnetic field gradients and their effects on imaging at low magnetic field strengths
Norris, D. G., & Hutchison, J. M. S. (1990) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(90)90209-k · Cited by 127
Real‐time autoshimming for echo planar timecourse imaging
Ward, H. A., Riederer, S. J., & Jack, C. R. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10259 · Cited by 82
Optimized distortion correction technique for echo planar imaging
Chen, N., & Wyrwicz, A. M. (2001) · Magnetic Resonance in Medicine · Cited by 77
Xiong (1999) · doi:10.1002/(sici)1097-0193(1999)8:2/3
Cited by
Lead-DBS: A toolbox for deep brain stimulation electrode localizations and visualizations
Horn, A., & Kühn, A. A. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2014.12.002 · Cited by 667
Stimulus Predictability Reduces Responses in Primary Visual Cortex
Alink, A., Schwiedrzik, C. M., Kohler, A., Singer, W., & Muckli, L. (2010) · The Journal of Neuroscience · doi:10.1523/jneurosci.3730-10.2010 · Cited by 435
Disentangling common and specific neural subprocesses of response inhibition
Sebastian, A., Pohl, M. F., Klöppel, S., Feige, B., Lange, T., Stahl, C., Voss, A., Klauer, K. C., Lieb, K., & Tüscher, O. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.09.020 · Cited by 193
Ball, T., Rahm, B., Eickhoff, S. B., Schulze-Bonhage, A., Speck, O., & Mutschler, I. (2007) · PLoS ONE · doi:10.1371/journal.pone.0000307 · Cited by 176
Self-citationThe medial forebrain bundle as a target for deep brain stimulation for obsessive-compulsive disorder
Coenen, V. A., Schlaepfer, T. E., Goll, P., Reinacher, P. C., Voderholzer, U., Tebartz van Elst, L., Urbach, H., & Freyer, T. (2017) · CNS Spectrums · doi:10.1017/s1092852916000286 · Cited by 128
Metadata
- Authors
- Zaitsev, M., Hennig, J., & Speck, O.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2004-10-26
- Volume
- 52
- Issue
- 5
- Pages
- 1156-1166
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1998694073
- Cited by
- 349
- References
- 23
- FWCI
- 4.81
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.