The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Manganese‐enhanced magnetic resonance imaging of mouse brain after systemic administration of MnCl2: Dose‐dependent and temporal evolution of T1 contrast
Abstract
Manganese is a useful contrast agent for MRI of animals. Previously, it has been shown that systemic doses of MnCl 2 provide unique contrast in the rodent brain, enabling visualization of neuroarchitecture. The present work investigates the dose and temporal dependence of brain enhancement after i.v. administration of MnCl 2. Varying doses of MnCl 2 (9–175 mg/kg) were administered to mice from 0 to 24 h prior to T1‐weighted manganese‐enhanced MRI (MEMRI) at 11.7 T. Pre‐MnCl 2 T1 values measured in different brain regions ranged from 1.17 ± 0.03 to 1.76 ± 0.01 s. Post‐MnCl 2 T 1 measured 24 hr after administration of MnCl 2 were significantly decreased, even after the lowest dose of MnCl 2. The largest decreases occurred in the pituitary gland, where post‐MnCl 2 T1 ranged from 231 ± 23 ms following the lowest dose to 143 ± 43 ms after the highest dose, while the smallest decreases were observed in cortex (post‐MnCl 2 T1 = 1060 ± 5 ms for low dose and 637 ± 5 ms for high dose). The contrast resulting after 14 hr did not change up to 24 hr. Enhancement first occurred in subarachnoid spaces, followed by ventricles and periventricular tissues, and finally reached the remainder of the brain. Cortical layers were detected at higher doses (>88 mg/kg) and olfactory bulb layers were detected with the lowest dose (9 mg/kg). Temporal evolution of the enhancement of the olfactory bulb layers was observed. In some regions of the brain, such as hippocampus and thalamus, the changes in contrast detected between 2 and 14 hr used very specific pathways. These results demonstrate that both the dose and the time after MnCl 2 can be manipulated to optimize brain contrast in a region‐specific manner. Published 2005 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cloning and characterization of a mammalian proton-coupled metal-ion transporter
Gunshin, H., Mackenzie, B., Berger, U. V., Gunshin, Y., Romero, M. F., Boron, W. F., Nussberger, S., Gollan, J. L., & Hediger, M. A. (1997) · Nature · doi:10.1038/41343 · Cited by 3,166
Rennels, M. L., Gregory, T. F., Blaumanis, O. R., Fujimoto, K., & Grady, P. A. (1985) · Brain Research · doi:10.1016/0006-8993(85)91383-6 · Cited by 752
Iron-dependent regulation of the divalent metal ion transporter
Gunshin, H., Allerson, C. R., Polycarpou-Schwarz, M., Rofts, A., Rogers, J. T., Kishi, F., Hentze, M. W., Rouault, T. A., Andrews, N. C., & Hediger, M. A. (2001) · FEBS Letters · doi:10.1016/s0014-5793(01)03189-1 · Cited by 305
Cited by
Development of a T1 Contrast Agent for Magnetic Resonance Imaging Using MnO Nanoparticles
Na, H. B., Lee, J. H., An, K., Park, Y. I., Park, M., Lee, I. S., Nam, D., Kim, S. T., Kim, S., Kim, S., et al. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200604775 · Cited by 614
Self-citationManganese‐enhanced magnetic resonance imaging (MEMRI): methodological and practical considerations
Silva, A. C., Lee, J. H., Aoki, I., & Koretsky, A. P. (2004) · NMR in Biomedicine · doi:10.1002/nbm.945 · Cited by 486
Self-citationIn Vivo mouse imaging and spectroscopy in drug discovery
Beckmann, N., Kneuer, R., Gremlich, H., Karmouty‐Quintana, H., Blé, F., & Müller, M. (2007) · NMR in Biomedicine · doi:10.1002/nbm.1153 · Cited by 118
Rollins, C. P. E., Gallino, D., Kong, V., Ayranci, G., Devenyi, G. A., Germann, J., & Chakravarty, M. M. (2019) · NeuroImage: Clinical · doi:10.1016/j.nicl.2018.11.016 · Cited by 79
Bosse, K. E., Ghoddoussi, F., Eapen, A. T., Charlton, J. L., Susick, L. L., Desai, K., Berkowitz, B. A., Perrine, S. A., & Conti, A. C. (2019) · Brain Imaging and Behavior · doi:10.1007/s11682-018-9856-6 · Cited by 10
Metadata
- Authors
- Lee, J. H., Silva, A. C., Merkle, H., & Koretsky, A. P.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2005-02-18
- Volume
- 53
- Issue
- 3
- Pages
- 640-648
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2165298588
- Cited by
- 170
- References
- 3
- FWCI
- 10.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.